69
Chapter 4 Basic operations
Inserting the scope
While observing the monitor screen, confirm the correct insertion direction and
insert the scope slowly. Perform the angulation operation as required during
insertion. Be careful not to apply excessive pushing force, twisting or tension to
the insertion tube.
WARNING
•
It is designed for safety with a double screw construction. If the optical adapter starts to
become detached from the distal end of the scope, the illumination will cease and a message
will be displayed, as shown below. The optical adapter may fall off the scope if used in this
condition. In this case, immediately stop the inspection, withdraw the scope carefully and
secure the optical adapter as described in the operating procedure.
•
Be sure to turn the illumination light on during insertion into the object being examined. The
illumination light does not light if the optical adapter is not correctly attached to the distal end
of the scope.
•
Read and understand the contents of “Important Information – Please Read Before Use”
(page 4) before using the scope. In case of any questions, contact Olympus.
If the optical adapter is not properly attached
Summary of Contents for IPLEX FX IV8000-2
Page 1: ...INSTRUCTIONS INDUSTRIAL VIDEOSCOPE IPLEX FX series ...
Page 2: ......
Page 10: ...2 2 Rating plate B 3 LCD monitor warning plate ...
Page 203: ...195 Chapter 10 Specifications ...
Page 206: ...198 ...
Page 207: ......