6320 Sander
OLIVERMACHINERY.NET
13
|
Page
Electrical Wiring
The single phase variant of his machine is pre-wired with a cord and a NEMA 6-15 plug. See
on page 35 for wiring the three phase variant.
To connect the machine directly to the electrical panel (
“
Hardwiring
”
), ensure an electrical disconnect is
installed near the machine so the operator or service person can easily disconnect the machine from
power.
To connect this machine with a plug and a cord, use a UL/CSA listed plug that meets the power
requirements. Organize the power cord so it does not create a tripping hazard.
The use of an extension cord is not recommended. If you need to use an extension cord to connect to a
power source, select a durable cord type with a high-temperature rating (90C° or above). Use the
minimum amount of extension cord as needed.
Minimum cord size (AWG) required based on amperage draw and length of the cord:
Amps
Power Cord Length
25 feet
50 feet
75 feet
100 feet
8 to 12
14
14
12
10
12 to 15
12
12
10
10
15 to 20
10
10
10
NR
21 to 30
10
NR
NR
NR
*NR: Not Recommended
WARNING
Use properly sized wires that meet or exceed the power requirement of your
machine. Using undersized wires may cause overheating and increase the risk of fire
and machine damage.
Summary of Contents for 6320
Page 2: ......
Page 8: ...8 Page Oliver Machinery 6320 Sander Identification...
Page 37: ...6320 Sander OLIVERMACHINERY NET 37 Page Parts List Cabinet Stand...
Page 38: ...38 Page Oliver Machinery 6320 Sander Head Plate...
Page 39: ...6320 Sander OLIVERMACHINERY NET 39 Page Safety Guard System...
Page 40: ...40 Page Oliver Machinery 6320 Sander Table...
Page 41: ...6320 Sander OLIVERMACHINERY NET 41 Page Miter Gauge...
Page 50: ...50 Page Oliver Machinery 6320 Sander Maintenance Record Date Task Operator...
Page 51: ...6320 Sander OLIVERMACHINERY NET 51 Page Date Task Operator...
Page 52: ...52 Page Oliver Machinery 6320 Sander Notes...
Page 53: ...6320 Sander OLIVERMACHINERY NET 53 Page...
Page 55: ......