9
3.2
Work modes
The BRE-I-5K Series hybrid inverter has the following work modes based on your
configuration and layout conditions
Work mode: Self-use
Priority: load>battery>grid
1. Generated
solar
energy
2. Storage
in
Battery
3. Load
consumption
4. Grid
supply
power
Self-consumption of PV renewable energy is the highest priority. The PV excess is
used to charge the batteries, then fed back into the grid.
Work mode: Feed in Priority
Priority: load>grid>battery
This mode applies the area that has high feed-in tariff and export control.
The PV generated power will be used to supply the loads firstly, then feed into the
grid. The excess power will charge the battery