43967002TH Rev.1
79 /
Oki Data CONFIDENTIAL
3. Installation
3.4.2 Power cable connection
Required conditions for power supply
• The following conditions should be satisfied.
AC
: 100V ± 10%
Power frequency : 50 Hz or 60Hz ± 2Hz
• If the power supply is unstable, use the voltage regulator and equivalent.
• Maximum power consumption of this printer is 1,300 W. Confirm that the
power supply source has sufficient margin.
• When the UPS (Uninterruptible power supply) is used, operations are not
guaranteed. Explain clients not use the UPS (Uninterruptible power supply).
Warning
Failure to observe the warning may result
in fire and electric shock.
• Before connecting and disconnecting the power cord and earth wire, turn OFF the
POWER switch.
• The earth wire should be connected to the dedicated earth terminal. Never connect the
earth wire to city water pipe, city gas pipe, earth terminal of telephone line or lightening
rod.
• To disconnect and connect the power cord, be sure to hold the power plug.
• The power plug should be inserted to the deep end of power source connector without
fail.
• Do not disconnect and connect the power plug with wet hand.
• Place the power cord to the location where people do not step on it. Do not place any
object on top of the power cord.
• Do not bind nor tie the power cord while using it.
• Do not use the damaged power cord.
• Do not connect many loads on one electrical outlet.
• Do not share the same electrical outlet with other electric products. If air conditioner,
copying machine, paper shredder are connected in parallel, the MFP may malfunction
due to electric noise. If the MFP shares the same electrical outlet with other electric
products, use the noise filter or noise-cut transformer that is available on commercial
markets.
• Use only the power cord that is supplied with the MFP.
• Do not use the AC extension cord. If any extension cord is used by all means, use the
extension cord having rating of 15 A or more.
• If extension cord is used, AC power voltage may drop so that the MFP will not operate
normally.
• Do not turn OFF the power nor disconnect the power plug while printing is in progress.
• When the MFP is not gong to be used for long time due to vacation or trip, disconnect
the power cord.
Be sure to explain details of connecting the power cord and earth wire to clients while
showing the User’s Manual.
Connecting the power cord
Note!
Confirm that the POWER switch is set to OFF (O).
(1) Connect the power cord to the MFP.
(2) Connect the earth wire to the earth terminal. Insert the power plug to the electrical
outlet of power supply source.
Press the POWER switch to ON (|)
The following display appears on the Control Pane. When the MFP has started up completely,
the [ON LINE] display appears.
????????????????
PLEASE WAIT
ON LINE
RAM CHECK
INITIALIZING
[ON LINE] [Inspect] lamp and
backlight light ON
O
I
Earth terminal
Earth wire