Oki Data CONFIDENTIAL
43967002TH Rev. 1
186 /
4. Part Replacement
(3) Remove the spring from the paper cassette.
4.2.3.21 Paper feed roller (tray 1)
Note!
The paper feed roller and the separator piece should be replaced together as
a pair.
(1) Turn OFF the power of the MFP, and remove the paper cassette.
(2) While opening the feed paper roller (large) outside, remove it from the axis.
(4) Bend the separator piece until one foot of the separator piece is removed from
the pivot, and remove it in the manner of raising it up.
[Caution when installing the feed paper roller]
1. When installing the new feed paper roller, insert it into the axis, and insert it
securely by rotating it until it reaches the deep end. At the same time, confirm that
the roller does not come off.
Paper cassette
Claw
Spring
Flat head screwdriver
Separator piece:
Pivot
Flat head screwdriver
Flat head screwdriver
Foot
Separator piece: