Oki Data CONFIDENTIAL
45762101TH Rev.1
2-32
2. TROUBLESHOOTING PROCEDURES
Display
Cause
Error details
Measure
Inspection is
required.
182 : Error
Option unit I/F
error
Does the error occur again?
Does the error occur again?
Yes
Yes
Turn off and on the
MFP.
Be sure of connector
connection.
Replace the option
unit.
Power OFF/ON
190 : Error
System
memory
overflow
Does the error occur again?
Yes
Turn off and on the
MFP.
Replace the CU/PU
board.
Power OFF/ON
203 : Error
204 : Error
207 : Error
208 : Error
213 : Error
214 : Error
CU program
error (203
to 214 do
not occur in
general use of
the MFP)
Invalid processing was
performed with a CU
program.
Replace the CU/PU
board.
Power OFF/ON
209 : Download
error
Custom
Media
Type table
downloading
failure
Custom Media Type table
downloading failed.
Turn off and on the
MFP, and then re-
download it (In general
use of the MFP, this
downloading is not
performed and this
error does not occur).
Inspection is
required.
230 : Error
TAG Reader
not installed
Inspection is
required.
231 : Error *
TAG interface
error
IA TAG interface error was
detected.
Be sure the toner
cartridges and the
image drums are
properly set.
Replace the toner
cartridges. When the
error occurs again
after the image drums
are re-installed, be
sure of the cable
connection from the
CU/PU board to the
toner sensor board.
01 : A short-circuit error.
02 : TAG communication
error.
Inspection is
required.
250 : Error
Secure File
Erasing Error
Display
Cause
Error details
Measure
Inspection is
required.
251 : Error
Secure Disk
Erasing Error
PRESS POWER
SW FOR 5SEC
Error : 813
SU Com-
munication
Error
Communication error
between the Controller and
the Scanner Unit is detected.
Turn off and on the
MFP.
Power OFF/ON
923 : Error
A lock error
with black
image drum
The image drum does not
revolve properly.
Does the error display is
provided again by turning off
and on the MFP?
Yes
Yes
Be sure the image
drum is properly
installed properly.
Replace the image
drum unit.
Replace the image
drum motor.
Power OFF/ON
933 : Error
Tray-2
CPU clock
frequency
error
The error is occurred
when Factory mode
only.
Power OFF/ON
941 : Error
942 : Error
943 : Error
944 : Error
946 : Error
PU Error
A PU error was detected.
Turn off and on the
MFP.
When this error occurs
again, replace the CU/
PU board.
The 946 error is
occurred when Factory
mode only.
941 : Watch Doc Timer Error
942 : Detection of Unassigned
Interruption
943 : CPU Error Detection
944 : Dcon Access Error
946 : AC Voltage Zero-
crossing Error
Inspection is
required.
982 : Error
Excessive
Optional Tray
Detected
Inspection is
required.
984 : Error
Black Tag
Version
Mismatch
Note!
With the MFP’s temperature not more than 0ºC, Service call errors 171 Error
may occur. After turn off the MFP, turn on the MFP after the MFP warms.