Oki Data CONFIDENTIAL
45762101TH Rev.1
3-20
3. MAINTENANCE MENUS
4. While the message "PRINT EXECUTE" that is set by the operation specified in step
2 is being displayed, press the [6] key and the test print is executed with the setting
value that has been set by steps 2 and 3.
Pressing the [#] key stops the test print.
If any alarm that is shown in the following details column is issued at startup of test
print or while test print is in progress, the test print is interrupted. (For error details,
refer to section 2.5.1 LCD Status Message/ Trouble Table. However, the comment
to be displayed is different in the case of the PU test print.)
Panel display
Details
PAPER END
SELECTED TRAY
No paper
SELECTED TRAY IS
NOT INSTALLED
Selected tray is not installed.
INSTALL CASSETTE TRAY
OPEN
Cassette removal
Print pattern (It cannot be used for checking PQ.)
0:Write paper print
1:2x2 print
2:4x4 print
3:Horizontal line print
4:Slash line print
5:Vertical line print
6:White paper print
7:Black paper print
8 to 15:White paper print
• During printing, the following messages are displayed.
P=***
P : Number of test print copies (unit: copies)
• Displays are switched by pressing the [2] key.
T=*** U=***[###]
H=***%
U : *** = Upper heater temperature measurement value [unit: ]
[***] = Print execution target temperature [unit: ]
T : Environment temperature measurement value [unit: ]
H : Environment humidity measurement value [unit: % ]
• Displays are switched by pressing the [2] key.
KTR=*.**
KTR indicate the transfer voltage setting value. (unit: KV)