Oki Data CONFIDENTIAL
45762101TH Rev.1
3-21
3. MAINTENANCE MENUS
• Displays are switched by pressing the [2] key.
KR=*.**
KR : BLACK transfer roller resistance value [unit: uA]
• Displays are switched by pressing the [2] key.
ETMP=***UTMP=***
ETMP : Environment temperature [unit: DEC]
UTMP : Fuse target temperature [unit: DEC]
• Displays are switched by pressing the [2] key.
DB:k**
DB
: Develop voltage setting table ID number [unit: HEX]
•
Displays are switched by pressing the [2] key.
TR1:k**
TR2:k**
TRl
: Transfer voltage parameter VTR1 table ID number [unit: HEX]
TR2
: Transfer voltage parameter VTR2 table ID number [unit: HEX]
•
Displays are switched by pressing the [2] key.
TROFF:**
TROFF : Transfer OFF voltage setting table ID number [unit: HEX]
5. Repeat steps 2 to 4 as required.
6. Pressing the [#] key terminates the test. (Returns to the status of step 1.)