4.REPLACEMENT OF PARTS
4.2.16 Cover Assy Stacker
(1) Remove the Scanner unit. (Refer to 4.2.8)
(2) Remove the Plate-Shield and CU/PU Board. (Refer to 4.2.3)
(3) Remove the Guide Cable . (Refer to 4.2.14)
(4) Remove the screw
①
.
(5) Remove the two screws (Silver)
②
. Remove the Cover-Eject
③
and Plate-
Rear
④
.
(At this moment, Head cable is also removed.)
(6) With the Cover Assy Stacker closed, detach Lever-Link-Fuser
⑤
(on both
sides) from the Cover Assy Stacker.
①
④
③
②
②
Closed the Cover Assy Stacker
⑤
Release lever