Chapter 2. Functions
2-32
n
Note 1
n
________________________________________________________________________________________________________________
Counting is enabled during real-time emulation and disabled during single-step emulation.
________________________________________________________________________________________________________________________________
n
Note 2
n
________________________________________________________________________________________________________________
The trigger fires just before execution of the instruction at the corresponding address, so the
instruction at the start address is counted, but not the one at the stop address.
Counting covers from the MOV A,#3H
instruction at the start address through
to the INCB HL instruction preceding
the stop address.
Count start
address
Count stop
address
MOV A, #3H
MOV H, #0FH
MOV L, #0H
INCB HL
MOV [HL], A
________________________________________________________________________________________________________________________________
n
Note 3
n
________________________________________________________________________________________________________________
Only start and stop address specifications corresponding to the first word of an instruction
produce results. One specifying the second word of a two-word instruction or an entry in the
ROM table yield a trigger that never fires.
________________________________________________________________________________________________________________________________
Summary of Contents for Dr.63514
Page 4: ...Table of Contents...
Page 7: ...Preface...
Page 15: ...Chapter 1 Overview...
Page 22: ...Chapter 2 Functions...
Page 69: ...Chapter 3 Setting Up and Starting Up...
Page 76: ...Chapter 4 Additional Usage Notes...
Page 88: ...Appendices...
Page 94: ...Appendices A 7 black brown red orange yellow green blue purple Figure A 4 Probe cable layout...