![Oki C3200n Service Manual Download Page 38](http://html2.mh-extra.com/html/oki/c3200n/c3200n_service-manual_3711998038.webp)
42615101TH Rev.8
38 /
Oki Data CONFIDENTIAL
How to check errors and Handling of the errors
Confirm with the color registration adjustment test of the self-diagnostic mode (Section 5.4.2.7)
Handling for each error
•
CALIBRATION ERR, DENS SENSOR ERR
Check 1
Check a connection state of the sensor cable when the above message
appears.
Correct to a normal state if the connection state is wrong.
Check 2
Check that the surface of the sensor is clean without paper dust and toner.
Wipe it off if it is dirty.
•
EDENS SHUTTER ERR
Check 3
Check whether an opening-closing motion of the sensor shutter is normal with
MOTOR&CLUTCH TEST of the self-diagnostic mode.
•
DENS ID ERR
Check 4
Check that there is no abnormal blushing on a drum surface by taking an ID unit
out.
Exchange a LED head (Defocusing) or exchange an ID unit.
Apply FUSE KEEP MODE of the maintenance menu when a new ID unit is used
as a test.
Summary of Contents for C3200n
Page 1: ...Oki Data CONFIDENTIAL C3200n C5150n C5200n C5400n C5510MFP Service Manual 060125A...
Page 2: ...42615101TH Rev 8 2 Oki Data CONFIDENTIAL...
Page 11: ...42615101TH Rev 8 11 Oki Data CONFIDENTIAL...
Page 13: ...42615101TH Rev 8 13 Oki Data CONFIDENTIAL...
Page 43: ...42615101TH Rev 8 43 Oki Data CONFIDENTIAL C5510 Handle Holes each on side or on end...
Page 65: ...42615101TH Rev 8 65 Oki Data CONFIDENTIAL Sample In case of C5200 C5150 C3200n...
Page 80: ...42615101TH Rev 8 80 Oki Data CONFIDENTIAL 1 2 3 4 5...
Page 84: ...42615101TH Rev 8 84 Oki Data CONFIDENTIAL 1 2 3 4 5 6 7 8 9 0 A B C...
Page 255: ...Oki Data CONFIDENTIAL 42615101TH Rev 8 255...