44951501TH Rev.2
7-19
Oki Data CONFIDENTIAL
7. TROUBLESHOOTING
Display
Causes
Error detail
Actions
SERVICE CALL
067:ERROR
068:ERROR
Interface
monitor error
SERVICE CALL
069:ERROR
NIC Chip
error
Is the error display provided
again?
Yes
Turn off and on
the printer.
Replace the CU/
PU board.
POWER OFF/ON
070:ERROR
PostScript
error
POWER OFF/ON
072:ERROR xx
Engine
interface error
or PU-CU
interface error
Is the CU/PU board installed
properly?
No
Yes
Reinstall the CU/
PU board properly.
Replace the CU/
PU board.
POWER OFF/ON
073:ERROR
xxxxxxxx
Video error.
An error was
detected in
expanding
image data
(an invalid
data was
received)
Is the CU/PU board installed
properly?
Does the error occur again?
No
Yes
Yes
Reinstall it
properly.
Change the
PC to a high-
specification one
or decrease the
resolution, and
perform printing
again.
Replace the CU/
PU board.
Replace the
interface cable.
Reinstall the PC
printer driver.
Is the CU/PU board installed
properly?
Does the error occur again?
Does the error depend on
print data?
No
Yes
Yes
No
Yes
Reinstall it
properly.
Perform printing
again.
Print other data.
Replace the CU/
PU board.
Ask design
people to analyze
the data.
Display
Causes
Error detail
Actions
POWER OFF/ON
074:ERROR
xxxxxxxx
075:ERROR
xxxxxxxx
Video error.
An error was
detected in
expanding
image data.
Is the CU/PU installed
properly?
No
Yes
Reinstall it
properly.
Replace it.
SERVICE CALL
081:ERROR
Parameter
matching
check error
Reading from or writing into
EEPROM or flash memory
cannot be made properly.
Turn off and
on the printer.
Replace the CU/
PU board when
the symptom
persists.
SERVICE CALL
104:ERROR
An engine
EEPROM
read/write
error was
detected.
Does the error occur again?
Yes
Turn off and on the
printer
Replace the CU/
PU board.
SERVICE CALL
106:ERROR
Engine
control logic
error
Does the error occur again?
Yes
Turn off and on the
printer
Replace the CU/
PU board.
SERVICE CALL
112:ERROR
The 2nd tray
for a model
different from
the printer
was detected.
Is the 2nd tray for the printer
installed?
No Install proper 2nd
tray.
SERVICE CALL
121:ERROR
High-voltage
power supply
interface error
Is the cable between the CU/
PU board and the high-voltage
power unit connected properly?
Is a contact faulty?
No
Yes
No
Reconnect it
properly.
Check the high-
voltage line for no
poor connection.
Replace the high-
voltage power
supply.