44951501TH Rev.2
7-28
Oki Data CONFIDENTIAL
7. TROUBLESHOOTING
(2-3) Bad odor is generated
Check item
Check operation
Actions for NG
results
(2-3-1) Bad odor locating
Fuser unit
Remove the fuser unit and check the odor.
Implement
section (2-3-2).
Low voltage power
supply unit
Remove the low voltage power supply unit and
check the odor.
Replace the low
voltage power
supply unit
(2-3-2) Fuser unit check
Life count of fuser
unit
Check the life count of the fuser unit by using
the self-diagnostic mode.
The fuser close
to the new fuser
unit smells
some odors.
Check that no
foreign material
exists in fuser unit.
Check that no foreign materials such as paper
are stuck inside of the fuser unit.
Remove the
foreign material.
(2-4) Startup time of printer is long
Check item
Check operation
Actions for NG
results
(2-4-1) Fuser unit check
Halogen lamp
Checkthat100Visshownonthelabelonthe
rearofthefuserunit.
Replace the
fuser unit.
(2-4-2) Option part check (note)
Extension memory
Reinstall the option part (the extension
memory) and check operation.
Replace the
option part.
SD memory card
Reinstall the option part (the SD memory
card) and check operation.
Replace the
option part.
Note!
When the printer has a problem, for example it does not start properly, remove
any CU options (RAM and SD memory card) and check for changes.