44951501TH Rev.2
7-21
Oki Data CONFIDENTIAL
7. TROUBLESHOOTING
Display
Causes
Error detail
Actions
SERVICE CALL
154:ERROR
Belt unit fuse-
cut error
Is the belt unit installed
properly?
Does the error occur again?
No
Yes
Yes
Re-install it.
Turn off and on
the printer.
Be sure of cable
connection, and
then replace the
CU/PU board.
SERVICE CALL
155:ERROR
Fuser unit
fuse-cut error
Is the fuser unit installed
properly?
Does the error occur again?
No
Yes
Yes
Clean the
connection
connector of the
fuser unit, and
then re-install the
fuser unit.
Turn off and on
the printer.
Be sure of cable
connection, and
then replace the
CU/PU board.
SERVICE CALL
160:ERROR
163:ERROR
Toner sensor
detection
error (160=Y,
161=M,
162=C,
163=K).
This error
does not
occur with
the printer in
the factory
shipped
configuration.
Is the toner cartridge
installed?
Is the toner slide shutter set?
No
No
Yes
Install the toner
cartridge.
Turn it to the fixed
position. Turn off
and on the printer.
Replace the toner
sensor assembly.
SERVICE CALL
167:ERROR
Thermistor
slope error
Does an error message
appear?
Does the error occur again?
Yes
Turn off and on
the printer.
Turn off and on
the printer after
leaving it for 30
minutes.
Display
Causes
Error detail
Actions
SERVICE CALL
168:ERROR (Note)
Compensation
thermistor
error
Does an error message
appear?
Does the error occur again?
Yes
Turn off and on
the printer.
Turn off and on
the printer after
leaving it for 30
minutes.
SERVICE CALL
170:ERROR
171:ERROR (Note)
A fuser
thermistor
short or open
circuit was
detected.
Does the error occur again?
Yes
Turn off and on
the printer.
Replace the fuser
unit.
SERVICE CALL
172:ERROR
173:ERROR
A fuser
thermistor
temperature
error (high
or low
temperature)
was detected.
Does the error occur again?
Does the error occur again?
Yes
Yes
Turn off and on
the printer.
Replace the fuser
unit.
Replace the low-
voltage power
supply, and then
replace the CU/
PU board when
the error occurs
again.
SERVICE CALL
174:ERROR
A backup
thermistor
shot circuit
was detected
(high
temperature)
Does the error occur again?
Yes
Turn off and on
the printer.
Replace the fuser
unit.
SERVICE CALL
175:ERROR (Note)
A backup
thermistor
open
circuit was
detected (low
temperature)
Does the error occur again?
Yes
Turn off and on
the printer.
Replace the fuser
unit.