44951501TH Rev.2
7-22
Oki Data CONFIDENTIAL
7. TROUBLESHOOTING
Display
Causes
Error detail
Actions
SERVICE CALL
176:ERROR
177:ERROR
A backup
thermistor
temperature
error (high
or low
temperature)
was detected.
Does the error occur again?
Does the error occur again?
Yes
Yes
Turn off and on
the printer.
Replace the fuser
unit.
Replace the low-
voltage power
supply.
SERVICE CALL
182:ERROR
Option unit
interface error
Does the error occur again?
Yes
Yes
Turn off and on
the printer.
Be sure of
connector
connection.
Replace the
option unit.
POWER OFF/ON
190:ERROR
System
memory
overflow
Does the error occur again?
Yes
Turn off and on
the printer.
Replace the CU/
PU unit.
SERVICE CALL
200:ERROR
202:ERROR
PU firmware
download
error
An error occurred in re-writing
the PU firmware.
Turn off and on
the printer, and
then re-download
it (In general use
of the printer, this
re-writing is not
performed and
this error does not
occur).
POWER OFF/ON
209:DOWNLOAD
ERROR
Custom
Media
Type table
downloading
failure
Custom Media Type table
downloading failed.
Turn off and on
the printer, and
then re-download
it (In general use
of the printer, this
downloading is
not performed
and this error
does not occur).
Display
Causes
Error detail
Actions
POWER OFF/ON
203:ERROR
204:ERROR
207:ERROR
208:ERROR
213:ERROR
214:ERROR
F0C:ERROR
FFE:ERROR
FFF:ERROR
CU program
error (203
to 214 do
not occur in
general use
of the printer)
Invalid processing was
performed with a CU program.
Replace the CU/
PU board.
SERVICE CALL
231:ERROR
TAG interface
error
A TAG interface error was
detected.
01: A circuit error.
03: TAG communication error.
Be sure the toner
cartridges and
the image drums
are properly set.
Replace the toner
cartridges. When
the error occurs
again after the
image drums
are re-installed,
be sure of the
cable connection
from the CU/PU
board to the toner
sensor board.
POWER OFF/ON
250:ERROR
SD card error
SERVICE CALL
251:ERROR
SD card
erasure error
POWER OFF/ON
252:ERROR
255:ERROR
SD card
security error
POWER OFF/ON
256:ERROR
257:ERROR
SD card error