© 2015 OJ Electronics A/S
46
reset to factory settings - room controllers
Write the room name in the box beside
each Ch number, and add ON if it is
controlled by a clock thermostat.
W
at
erline
r
oom Contr
oller -
type W
lC
t
3
Press the pinhole button R for 3 second. and the thermostat will
return to factory settings.
Remember to set time, day and area.
group
room
Ch 1
oFF
Ch 2
oFF
Ch 3
oFF
Ch 4
oFF
Ch 5
oFF
Ch 6
oFF
Ch 7
oFF
Ch 8
oFF
Ch 9
oFF
Ch 10
oFF
Ch 11
oFF
Ch 12
oFF
Ch 13
oFF
Ch 14
oFF
Example
Ch 1
Kitchen
on
Ch 2
living room
on
4-event times and temperatures
own settings
Standard
Mode
Radiator
mode
2-step mode
Hot water
mode
time
temperature
temperature
temperature
temperature
time
temperature
Days 1-5
06:00
21.0°C
21.0°C
21.0°C
50.0°C
08:00
19.0°C
19.0°C
19.0°C
30.0°C
16:00
22.0°C
22.0°C
22.0°C
50.0°C
22:30
17.0°C
17.0°C
17.0°C
30.0°C
Days 6-7
08:00
22.0°C
22.0°C
22.0°C
50.0°C
23:00
17.0°C
17.0°C
17.0°C
30.0°C
other settings
4-event sequence
-
4:52
4:52
4:52
4:52
High floor limit
temperature
-
27.0°C
-
27.0°C
-
Low floor limit
temperature
17.0°C
17.0°C
-
17.0°C
-
special settings
2-step time
-
-
-
60 min
-
2-step temperature
difference
-
-
-
2.0°C
-
NOTE: If more than one WLCT3 is present in the system, please copy this page.