The maximum permissible floor temperature setting is shown. Use the
UP (
△
) or DOWN (
▽
) button to increase or reduce the setting, then press
the OK (√) button to accept.
The display now shows LoLi. Press the OK (√) button to continue.
The minimum permissible floor temperature setting is shown. Use the UP
(
△
) or DOWN (
▽
) button to increase or reduce the setting, then press the
OK (√) button to accept.
sCal - time format and temperature scale selection
You can select either °C or °F and 12 or 24 hour clock as follows:
Press the UP (
△
) or DOWN (
▽
) button to change the settings. Confirm
the required scale with the OK (√ ) button.
arEa - (group of rooms)
The rooms/channels set as part of the WLCT3 area will follow the automatic temperature settings of this room controller (4-event timer, min.
and max. floor temperature limits).
Set a channel (room) to ON if it is to be part of this area.
Example: An area could be the living room, kitchen, and children’s rooms, all of which have a high temperature requirement during the
afternoon and early evening and a lower temperature requirement during the morning and night. Each room has an associated channel
number (Ch1, Ch2, etc.) determined by the number of the output on the master which controls the valve/actuator for that room.
Example: A system may have the kitchen room sensor operating master output #4 and the children’s room sensor operating master output
#5. If the WLCT3 room controller is situated in the living room and operates output #1, the WLCT3 must be programmed to control output
channels 1, 4, & 5.