© 2015 OJ Electronics A/S
38
W
at
erline
r
oom Contr
oller -
type W
lC
t
3
arEa - (group of rooms)
The rooms/channels set as part of the WLCT3 area will follow the automatic temperature settings of this room controller (4-event timer, min. and
max. floor temperature limits).
Set a channel (room) to ON if it is to be part of this area.
Example: An area could be the living room, kitchen, and children’s rooms, all of which have a high temperature requirement during the
afternoon and early evening and a lower temperature requirement during the morning and night. Each room has an associated channel number
(Ch1, Ch2, etc.) determined by the number of the output on the master which controls the valve/actuator for that room.
Example: A system may have the kitchen room sensor operating master output #4 and the children’s room sensor operating master output #5.
If the WLCT3 room controller is situated in the living room and operates output #1, the WLCT3 must be programmed to control output channels
1, 4, & 5.
1. Press the UP (
△
) or DOWN (
▽
) button to select the channel/room.
2. Press the OK (√) button to view the ON/OFF settings.
3. Press the UP (
△
) or DOWN (
▽
) button to change the ON/OFF settings.
4. Press the OK (√) button to return to the channel/rooms select menu.
Set the channel/room (Ch) to ON if it is to follow the settings of this room
controller.
A total of 14 channels/rooms can be controlled.
NOTE: If the channel selector (hex encoder) is set to 1 .. 14, the selected
channel will always be ON (cannot be set to OFF).