© 2015 OJ Electronics A/S
43
W
at
erline
r
oom Contr
oller -
type W
lC
t
3
Pro - 4-event sequence
It is possible to change the factory-set sequence for Days 1-5 (4 events) and Days 6-7 (2 events).
Days 1 to 5 are usually Monday to Friday, while Days 6-7 are usually Saturday and Sunday.
An event is either a comfort temperature or a setback temperature. You can select from the following sequences, which are displayed in the
form of a code.
4 events for 5 days, 2 events for 2 days.
Indicated by code 4:52
Select the required sequence with the OK (√) button.
4 events for 6 days, 2 events for 1 day.
Indicated by code 4:61
Select the required sequence with the OK (√) button.
4 individual events for each day of the week. Indicated by Code 4:70
Select the required sequence with the OK (√) button.
2 individual events for each day of the week. Indicated by Code 2:70
Select the required sequence with the OK (√) button.
2 events for 5 days, 2 event for 2 days. Indicated by Code 2:52
Select the required sequence with the OK (√) button.
Escape without any changes
Hi li - Floor sensor Max. and min. permissible floor surface temperatures
A floor limit sensor can be connected to the room controller.
Max. limitation
is used for safety purposes to prevent excessive floor temperatures. Wooden flooring should, for example, not be allowed
to exceed 27°C. The value can be set from 5°C up to 55°C. The value can also be set to OFF by adjusting the temperature to 55°C and then
pressing the UP button once more.
Min. limitation
is used where the temperature of the floor must never fall below the set minimum temperature. Examples include kitchens or
bathrooms with tiles. The value can be set from 5°C to 55°C. The value can also be set to OFF by adjusting the temperature to 5°C and then
pressing the DOWN button once more. Remember that the max. limit temperature must be set higher than the min. limit temperature.
The limit temperatures defined in the room controller will be valid for all room sensors with floor limit sensor (type WLTD3) included in the area
allocated to the WLCT3 controller.
Summary of Contents for WLM3
Page 55: ... 2015 OJ Electronics A S 55 ...