background image

Defender 6000 Indicators

 

 

EN-5 

 

1.4. 

Mainboard

 

.Figure 1-3 i-DT61PW Mainboard 

Item   Description 

IR Communication connector (J6) 

Security Switch (SW1) 

Load Cell connector (J7) 

Load Cell Terminal Block (J8) 

 

 

Figure 1-4 i-DT61XWE Mainboard 

 

Item 

Description 

Item 

Description 

Alibi Memory Board connector (J19) 

Keyboard connector (J1) 

Discrete I/O/Analog/RS232-RS485-USB 

Device connector (J11) 

Load Cell connector (J12) 

Display Board connector (J2) 

Load Cell Terminal Block (J3) 

Ethernet connector (J10) 

Security Switch connector (SW1) 

RS232 connector (J5) 

10 

Discrete Input0 (J16) 

10 

Summary of Contents for Defender i-DT61PW

Page 1: ...Defender 6000 Indicators Instruction Manual 5 Commonwealth Ave Woburn MA 01801 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com...

Page 2: ......

Page 3: ...and Statistics 16 3 2 3 Check 17 3 2 4 Application Settings 18 3 3 COUNTING MODE 19 3 3 1 Enter the Mode 19 3 3 2 Establish an APW 19 3 3 3 Start Counting 19 3 3 4 Application Settings 19 3 4 PERCENT...

Page 4: ...O Type 46 4 9 2 Input 47 4 9 3 Output 47 4 10 LOCK KEY CONFIGURATION 47 4 11 LIBRARY FOR I DT61XWE MODEL 48 4 12 USER FOR I DT61XWE MODEL 50 4 13 USB FOR I DT61XWE MODEL 52 4 13 1 USB Flash Drive 52...

Page 5: ...equipment such that it is difficult to reach the power connection Only connect the power cord to a compatible grounded electrical outlet Make sure that the power cord does not pose a potential obstacl...

Page 6: ...Indicator Item Description 1 Control Panel 2 Front Housing 3 Screws 4 4 Load Cell Connector 5 Bottom Housing 6 Strain Relief for Option 7 Power cord Item Description 1 Control Panel 2 Front Housing 3...

Page 7: ...Figure 1 4 i DT61XWE Mainboard Item Description Item Description 1 Alibi Memory Board connector J19 6 Keyboard connector J1 2 Discrete I O Analog RS232 RS485 USB Device connector J11 7 Load Cell conn...

Page 8: ...re value When the accumulation data is displayed press to clear them Secondary Function Long Press Off If the terminal is On press to power off Units Changes the weighing unit Mode Allows changing the...

Page 9: ...again to unlock all buttons When all buttons are locked the icon will be lighted Figure 1 5 i DT61PW Display Item Description Item Description 1 Range symbol not used 12 Accumulation symbol 2 NET sym...

Page 10: ...ol 13 Dynamic tilde symbol 4 Stable weight symbol 14 Battery symbol not use 5 Preset Tare Tare symbols 15 Pound Ounce Pound Ounce symbols 6 Pointer symbols 16 Percent symbol 7 ID symbol 17 Kilogram gr...

Page 11: ...r input to i DT61PW Use 6 cells of D size dry batteries During battery operation the battery symbol indicates the battery status Battery 5 25 remaining Battery 25 50 remaining Battery 50 75 remaining...

Page 12: ...i DT61XWE 1 Remove the four hex head screws from the bottom housing 2 Open the housing by carefully pulling the bottom housing backward 3 Once all connections are made re attach the bottom housing Not...

Page 13: ...ell connector and wiring harness Before making the connections remove the pre installed load cell connector and wiring harness by following the following steps i DT61PW 1 Remove the 6 Phillips head sc...

Page 14: ...Defender 6000 Indicators i DT61XWE 1 Place the terminal down and unscrew the screws marked in the following graphic 2 Pull out the bottom of the terminal 3 Use a screw driver to unscrew the sealing c...

Page 15: ...T61XWE from external influences it is necessary to install a ferrite core on the load cell cable connected to the terminal The ferrite core is included with the terminal To install the ferrite simply...

Page 16: ...the analog load cell terminal blocks Note that when using four wire load cells jumpers must be placed between the Excitation and Sense terminals and between the Excitation and Sense terminals Figure 2...

Page 17: ...inal For details about Discrete Input0 function please refer to the Discrete I O for i DT61XWE section for details 2 4 Mounting Bracket Attach the bracket to a wall or table using fasteners not suppli...

Page 18: ...ss the M button to do acuumulation manually Auto AUtO the scale will perform accumulation automatically Accept ACCEPt the scale will perform accumulation automatically in the Check mode when the weigh...

Page 19: ...en i DT61XWE 1 Press the Target button from Weighing Counting Percent or Dynamic mode to set check limits 2 The display shows UNDEr 3 Press the Yes button to edit the under value 4 If there is a store...

Page 20: ...settings 1 Long press the Menu button until you see C A L Short press the No button several times until you see mM O d E Press the Yes button to enter the application mode settings 2 Short press the N...

Page 21: ...ss the Yes button to capture the current stable weight Note During the capture process the display shows i DT61PW You can press the button to tare The center of zero PT or NET icons will light as appr...

Page 22: ...s button to capture the current stable weight Note You can press the button to tare The center of zero PT or NET icons will light as appropriate For i DT61PW model during the capture process the displ...

Page 23: ...matic press the Function button to reset the countdown timer when the countdown is running The display shows rEAdY and start to re count When operation type is automatic remove the load from the pan a...

Page 24: ...e status press the Target button to resume the filling process The output port will be enabled or disabled according to the current load value 2 When the scale is in start status press the Target butt...

Page 25: ...e forth one orange 6 Nevertheless if the total load is more than SP4 all the four columns turn to red and the instrument will be in a stop state 3 6 5 Application Settings The application can be custo...

Page 26: ...Ge End For i DT61XWE model C A L S E t U P r E A d mM O d E U n i t G mM P R s 2 3 2 P r I N t I O L o c k L I b U S E r U S B E n d ZErO SpaN LINE GEO C test End reset C UNIt raNGe CAP1 Grad1 CAP2 Gr...

Page 27: ...middle level menu The Exit button exits from menu directly to the active weighing mode For menu items with numeric settings such as Capacity the current setting is displayed with all digits flashing T...

Page 28: ...utton to establish the zero point 4 The display shows C and then DONE when the Zero calibration is finished Note If zero calibration is failed or if after 40 seconds the calibration is still not succe...

Page 29: ...61PW short press the No button several times until the desired digit appears Short press the Yes button to accept the digit and move to the next one Repeat the process until all the digits are correct...

Page 30: ...ed digit appears Short press the Yes button to accept the digit and move to the next one Repeat the process until all the digits are correct Press the Yes button to accept the calibration point i DT61...

Page 31: ...ment Setup S E t U P Reset reset no yes NO yes Capacity Unit C UNIt kg lb Range raNGe Single Dual SINGLe DUal 1 Capacity CAP1 1 999999 1 Graduation Grad1 0 0001 100 2 Capacity Range Dual CAP2 1 999999...

Page 32: ...nal functions with two intervals each with its own capacity and graduation In addition to the Interval 1 capacity and graduation parameters the following two parameters are available 2 Capacity 2 Grad...

Page 33: ...ext Transaction Counter t NEXt Set the value of the next transaction displays in the Next Transaction field 1 999999 Key Beeper K Beep Set whether the beeper is enabled when a button is pressed Off no...

Page 34: ...nfrared Radiation Sensor OFF the IR sensor is disabled LOW the sensor will respond within 50mm 2 inches HIGH the sensor will respond within 100mm 4 inches Note This setting is only avaliable for i DT6...

Page 35: ...in 5min OFF 0 5 1 2 5 End End Reset reset Reset the readout menu to factory defaults NO do not reset YES reset Stability StAblE Set the amount the reading can vary before the stability symbol turns of...

Page 36: ...abled after 5 minute of no activity 10 the screensaver is enabled after 10 minute of no activity 30 the screensaver is enabled after 30 minute of no activity Lock Key L kEy Set to lock all keys after...

Page 37: ...the submenu value will be set to default Data Format d FmMt Set the date format MDY mMDY Month Day Year DMY DmMY Day Month Year YMD YmMd Year Month Day Date Date Set the date according to the previous...

Page 38: ...external communication methods and to set printing parameters Data may be output to either a printer or PC Factory default settings are shown in bold 4 7 1 RS232 Menu Enter this menu to define communi...

Page 39: ...ting is T Alternate Zero command Alt z Set the alternate command character for Zero Settings of A a to Z z are available The default setting is Z End End Advance to the next menu or return to the top...

Page 40: ...is within the acceptable range and stability criteria is met Interval IntEr If Interval is selected the sub menu Time will display IntEr printing occurs at the defined time interval The time interval...

Page 41: ...ze print template you need to go to the ScaleMate software Select Print Template on the top bar and then double click items in the left column to select which ones you want to put in your print templa...

Page 42: ...4 8 1 Memory menu for i DT61PW model Status StatUs To enable or disable the memory function OFF to disable memory function ON to enable memory function Press the Print button to save weighing data Exp...

Page 43: ...bi record contains the following ID Gross Net weight tare weight and weight unit Date and time To check Alibi records you need to install the ScaleMate software Please contact an authorized dealer to...

Page 44: ...s 3 Pull out the bottom of the terminal 4 Take out the Alibi memory board and prepare to install it in the circled place 5 Insert the Alibi memory board into the slot as shown below Please make sure t...

Page 45: ...is installed properly 7 Pull the bottom of the terminal in and make sure all the screws marked in step 2 are tightened Note There is possibility that the button cable is detached from the bottom of th...

Page 46: ...ory board pass the button cable through the bottom of the meter 2 And pull it under the FPC socket Push the button cable further under the FPC socket so that the cable is firmly attached 3 Use a tweez...

Page 47: ...6000 Indicators EN 45 4 Make sure the whole FPC socket are pushed in and the button cable is attached to it firmly 5 Repeat the previous step 7 to push in the bottom of the terminal and tighten all th...

Page 48: ...2 INPUt2 Off Zero Tare Clear Tare Print Unit Accumulate Start Reset Start Stop Pause Resume OFF ZErO tArE CLr tAr PrINt UNIt ACCUmM StArt rESEt StA SP PA rE Discrete Output1 OUt1 Off Overload Underloa...

Page 49: ...UNIt The external input initiates a Unit function ACCUmM The external input initiates an Accumulate function StArt The external input initiates a Start function rESEt The external input initiates a R...

Page 50: ...supports different items See the table below Item Mode PN Name Under Over Tare Reference weight APW F SP1 F SP2 F SP3 F SP4 Weighing X X X X X Percent X X X X X X Dynamic X X X X X Fill X X X X X X X...

Page 51: ...ercent PErCNt Dynamic dYNAmM and Filling FILL When you see the type you want press the Yes button Press the No button if you do not need to edit it and move on to the next item 7 Repeat step 6 to edit...

Page 52: ...input at least one number of the id through the numeric keyboard and then press the Yes button The first user id includes the number you input will be displayed Short press the No button to navigate b...

Page 53: ...user id in the library the terminal will recall the user When a user is in use an arrow on the screen will point to the user icon Later when you select user in the printing template the user s ID will...

Page 54: ...user ID to recall and use the related library item or user during weighing Use an RFID reader to input numbers when in the input mode Since there are many brands of RFID device in the market OHAUS te...

Page 55: ...through M25 hole 3 Close the USB Dongle Cover Note This cover is also an option please contact an authorized OHAUS dealer to get it 4 13 5 2 Configuration After inserting the dongle the indicator wil...

Page 56: ...Mask Subnet mask is 255 255 255 0 by default Gateway Gateway is 192 168 1 1 by default Primary DNS Secondary DNS DNS value is not needed when the system connects to a LAN and it is assigned by the IS...

Page 57: ...ings Before verification and sealing perform the following steps 1 Verify that the menu settings meet the local weights and measures regulations 2 Perform a calibration as explained in Calibration Men...

Page 58: ...aling of the cable is needed Once the indicator or the base is replaced by a new one an error message Error 8 9 will pop up in the indicator s displayed window When the i DT61PW or i DT61XWE indicator...

Page 59: ...eaning agents The housing may be cleaned with a cloth dampened with a mild detergent if necessary 6 1 1 Cleaning for i DT61PW Model The housing may be cleaned with a cloth dampened with a mild deterge...

Page 60: ...below Power On Zero limit 1 Add load to scale 2 Recalibrate scale Error 8 3 Weight reading exceeds Overload limit Reduce load on scale Error 8 4 Weight reading below Underload limit 1 Add load to scal...

Page 61: ...solution 1 75 000 Maximum approved resolution 1 10 000 EC OIML NTEP Class III Weighing Units Kilogram Gram Pound Ounce Pound Ounce Tonne Metric Tonne Modes Basic weighing Percent weighing Piece Counti...

Page 62: ...x LED Keyboard 6 function keys 12 alpha numeric capacitive keypad Auto zero Tracking Off 0 5 d 1 d or 3 d Load cell excitation voltage 5VDC Load cell drive Up to 4 x 350 ohm load cells Load cell input...

Page 63: ...4 13 13 12 12 11 42 19 43 26 17 16 16 15 15 14 14 13 13 12 12 43 26 44 32 17 17 16 16 15 15 14 14 13 13 12 44 32 45 38 18 17 17 16 16 15 15 14 14 13 13 45 38 46 45 18 18 17 17 16 16 15 15 14 14 13 46...

Page 64: ...aus com ce This product complies with the EU Directive 2012 19 EU WEEE and 2006 66 EC Batteries Please dispose of this product in accordance with local regulations at the collecting point specified fo...

Page 65: ...ested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when...

Page 66: ...ix digits no decimal point or sign Insignificant leading zeroes are replaced with spaces 4 Tare weight Six digits of tare weight data No decimal point in field 5 ASCII Carriage Return CR character 0D...

Page 67: ...1 and 0 Weight Description 2 1 0 0 0 0 lb or kg selected by Status Byte B bit 4 0 0 1 grams g 0 1 0 metric tons t 0 1 1 ounces oz 1 0 0 not used 1 0 1 not used 1 1 1 tons ton 1 1 1 no units Bit 3 Pri...

Page 68: ...nter P101 Print out stable weight value P102 Print out current weight value immediately SIRU Send weight value in the current unit immediately and repeat SIU Send weight value in the current unit imme...

Reviews: