52
13.1
Calibrating
This function is used to calibrate the supply of the valves, allowing the
release of the perfect amount preset from the
“Wine Setting”.
Calibrating Menu
LOAD
100Mls?
SAVE
EXIT
TASTE
NO
SI
(
+
/
-
)
tap
da 1 a 8
13.
Operation from the main menu
These features can be seen on the central display.
fig. 1
or 1 to 4
Manual of Use
53
Operation
Press the "P" key on the top left
and enter the
Main Menu,
then
press
, the key to activate the scrolling with the arrow keys and
select Calibrating
Once this function is selected, the center LED of each nozzle lights to
allow selecting which tap to work on (fig. 1).
Action
Function
LOAD
It is used to load the liquid initially for
dispensing.
TASTE
It is used to dispense a calibration supply
which must be equal to 100ml. You must
use a graduated cylinder of measuring
cup accurately degraded in ml.
SAVE
It is used to save the calibration parameters.
Exit
Exit from the menu without saving.
►
→
To perform a
Calibrating
procedure use a bottle filled with
750 ml of water.
100Mls ?
If the supplied amount is equal to 100ml
confirm with the
key, If it is not, use
the
and
keys to enter the actual
amount dispensed as measured using your
desired measuring device and confirm by
pressing the key
.
►
→
Bevore performing the
Calibrating
make sure to insert the
bottle using the appropriate procedure
►
→
cap. 9.4
57
Officine Gullo