8.3 Installation flush with front closure
FOR DISPENSERS WITH EXTERNAL CYLINDERS
When you close the machine front you must create an opening on the
back, at the bottom, as the air is now drawn from the bottom instead
of the frontal zone.
FOR DISPENSERS WITH INTERNAL CYLINDERS
When installing in a recessed structure please provide 200mm of
clearance on the back for the ventilation of the machine and extraction
of the gas cylinder.
This space must be open for the free passage of air and must have
access to exchange the cylinder.
The distance A shown below is the recommended distance from the
floor that can be 900 or 1000mm. The distance B is the minimum
distance for the cylinder extraction which is 200mm.