10
Nitrogen pressure with internal reg.
3-5 bar
Compressed air pressure
5 - 8 bar
Refrigerant used
R134A
Max cooling circuit pressure
10 bar
Nitrogen pressure with external reg.
max 200 mbar
Height
Maximum diameter
mm
mm
280÷355
100
4
Model
Voltage (USA -Canada )
Frequency
Max power draw refrigerated
110V
50-60
Hz
130 W
4 Bottles
Description
Bottle specifications
Unit
Description
Ambient temperature
Maximum relative humidity (Rhu)
Measurement
°C
Rhu
15÷27
70%
Installation environment specifications
This vector Illustration was created by DownloadFreeVector.com and itís
100% royalty free
for
commercial purposes
.
You can share it on your site with two backlinks - to DownloadFreeVector.com and to homepage of this vector freebie
(use post title as a text for link). In my work Iím using free vector silhouettes and Illustrations
from all-silhouettes.com and vectorlady.com (useful resources of free vector illustrations).
You are not allowed to share it without backlinks and sell it on stock sites as your own
(take care about your karma).
This vector Illustration was created by DownloadFreeVector.com and itís
100% royalty free
for
commercial purposes
.
You can share it on your site with two backlinks - to DownloadFreeVector.com and to homepage of this vector freebie
(use post title as a text for link). In my work Iím using free vector silhouettes and Illustrations
from all-silhouettes.com and vectorlady.com (useful resources of free vector illustrations).
You are not allowed to share it without backlinks and sell it on stock sites as your own
(take care about your karma).
Electrical Characteristics
Max power draw ambient temperature
50 W
Voltage EU
220V
Fuses for USA and Canada
F 4A
Fuses for Europe
F2.5A
Manual of Use
11
5.1 INCLUDED ACCESSORIES
The distributor is supplied with the following accessories:
→
copy of the installation manual paper or digital
→
warranty and compliance certificate
→
suction tubes
Any other accessories can be supplied in special versions.