33
GAET02307_002_10 - 06/2008 - © Œrlikon Leybold Vacuum
6
Troubleshooting
Fault
Possible cause
Remedy
Reference
section *
Pump does not
Pump is connected incorrectly.
Connect the pump correctly.
3.3
start.
Motor protection switch incorrectly set.
Set motor protection switch properly.
3.3
Operating voltage does not match motor.
Replace the motor.
Motor is malfunctioning.
Replace the motor.
Oil temperature is below 12 °C (54 °F).
Heat the pump and pump oil or use
1.8
different oil.
Oil is too viscous.
Use appropriate oil grade.
5.4-B
Exhaust filter / exhaust line is clogged.
Replace the filter or clean the exhaust line.
5.4-D
Pump is seized up.
Repair the pump.
5.4-J/5.4-K
(Sign : pump is jammed).
Pump does not
Measuring technique or gauge is unsuitable. Use correct measuring technique and gauge. 4.3
reach ultimate
External leak
1)
.
Repair the pump.
pressure.
Float valve does not close.
Repair the valve.
5.4-H
Anti-suckback valve is malfunctioning.
Repair the valve.
5.4-G
Exhaust valve is malfunctioning.
Repair the valve.
5.4-I
Inadequate lubrication due to:
■
unsuitable or contaminated oil,
Change the oil (degas it, if necessary).
5.4-C
■
clogged oil filter,
Replace the oil filter.
5.4-C
■
clogged oil lines.
Clean the oil casing.
Vacuum lines are dirty.
Clean vacuum lines.
Pump is too small.
Check the process date; replace the
pump, if necessary.
Pumping speed is Dirt trap in the intake port is clogged.
Clean the dirt trap;
5.4-F/1.4
too low.
Precaution: install a dust filter in intake line.
Exhaust filter is clogged.
Install new filter elements.
5.4-D
Connecting lines are too narrow or
Use adequately wide and short
3.1
too long.
connecting lines.
Anti-suckback valve is hard to open.
Check spring free length.
After switching off System has a leak.
Check the system.
pump under
Anti-suckback is malfunctioning.
Repair the valve.
5.4-G
vacuum, pressure
in system rises
too fast.
Pump gets too
Cooling air supply is obstructed.
Set pump up correctly.
3.1
hot.
Cooler is dirty.
Clean the cooler.
Ambient temperature is too high.
Set pump up correctly.
3.1
Process gas is too hot.
Change the process.
Oil level is too low.
Add oil to reach the correct oil level.
5.4-A
Oil is unsuitable.
Change the oil.
5.4-C
Oil cycle is obstructed.
Clean or repair the oil lines.
Exhaust filter / exhaust line is obstructed.
Replace the exhaust filter, clean the
5.4-D
exhaust line.
Exhaust valve is malfunctioning.
Repair the valve.
5.4-I
Pump module is no longer usable.
Replace the pump module
5.4-J.
Troubleshooting
Summary of Contents for 10926
Page 36: ...36 GAET02307_002_10 06 2008 Œrlikon Leybold Vacuum fig 6 SV200 SV300 similar Spare parts ...
Page 38: ...38 GAET02307_002_10 06 2008 Œrlikon Leybold Vacuum Spare parts fig 7 SV200 SV300 similar ...
Page 40: ...40 GAET02307_002_10 06 2008 Œrlikon Leybold Vacuum fig 7 SV200 SV300 similar Spare parts ...
Page 42: ...42 GAET02307_002_10 06 2008 Œrlikon Leybold Vacuum ...