8
GAET02307_002_10 - 06/2008 - © Œrlikon Leybold Vacuum
Description
SV300
Technical Data
50 Hz
60 Hz
Nominal speed
1)
m
3
.h
-1
280
340
Pumping speed
1)
m
3
.h
-1
240
290
Ultimate partial pressure without gas ballast
1)
mbar
≤ 8.10
-2
≤ 8.10
-2
Ultimate total pressure
mbar
≤ 0,7
≤ 0,7
with gas ballast standard
1)
Water vapour tolerance :
■
with gas ballast standard
1)
or EM
mbar
30
40
■
with big gas ballast
1)
mbar
60
70
Water vapour tolerable load :
■
with gas ballast
1)
or EM
kg.h
-1
5.4
7.4
■
with big gas ballast
1)
kg.h
-1
10
12.5
Noise level
2)
dB (A)
70
74
Leak rate
mbar.I.s
-1
≤ 1.10
-3
≤ 1.10
-3
Mains voltage (Standard)
V
230 / 400
460
4)
For other voltages please contact
Œrlikon Leybold Vacuum
Motor power
kW
5.5
6.3
Type of protection
IP 55
IP 55
3)
Rated rotational speed
min.
-1
1450
1750
Oil capacity (min./max.)
l
8.5/11.5
8.5/11.5
Intake connection
G2
G2
NPT 2
3)
Exhaust connection
G2
G2
NPT 2
3)
1) to DIN 28400 and following numbers, with standard gas ballast
2) operated at the ultimate pressure without gas ballast, free-field measurement at a distance
of 1 m
3) please contact Œrlikon Leybold Vacuum
4) CEI: 460 V / NEMA: 200 - 300 / 460 V
Summary of Contents for 10926
Page 36: ...36 GAET02307_002_10 06 2008 Œrlikon Leybold Vacuum fig 6 SV200 SV300 similar Spare parts ...
Page 38: ...38 GAET02307_002_10 06 2008 Œrlikon Leybold Vacuum Spare parts fig 7 SV200 SV300 similar ...
Page 40: ...40 GAET02307_002_10 06 2008 Œrlikon Leybold Vacuum fig 7 SV200 SV300 similar Spare parts ...
Page 42: ...42 GAET02307_002_10 06 2008 Œrlikon Leybold Vacuum ...