1.2 Technical characteristics
Pump technical data like e.g. ultimate pressure & noise level are only valid
for standard pumps operating with the mentioned mineral oil. The use of
other oils may have consequences on these values.
SV200
Technical Data
50 Hz
60 Hz
Nominal speed
1)
m
3
.h
-1
180
220
Pumping speed
1)
m
3
.h
-1
170
200
Ultimate partial pressure without gas ballast
1)
mbar
≤ 8.10
-2
≤ 8.10
-2
Ultimate total pressure
mbar
≤ 0.7
≤ 0.7
with gas ballast standard
1)
Water vapour tolerance :
■
with gas ballast standard
1)
or EM
mbar
40
50
■
with big gas ballast
mbar
50
60
Water vapour tolerable load:
■
with gas ballast standard
1)
or EM
kg.h
-1
3.4
5.4
■
with big gas ballast
kg.h
-1
N/A
N/A
Noise level
2)
dB (A)
69
73
Leak rate
mbar.I.s
-1
≤ 1.10
-3
≤ 1.10
-3
Mains voltage (Standard)
V
230 / 400
460
4)
For other voltages
3)
Motor power
kW
4
4,6
Type of protection
IP 55
IP 55
3)
Rated rotational speed
min.
-1
1450
1750
Oil capacity (min./max.)
l
5/9
5/9
Intake connection
G2
G2
NPT 2
3)
Exhaust connection
G2
G2
NPT 2
3)
1) to DIN 28400 and following numbers, with standard gas ballast
2) operated at the ultimate pressure without gas ballast, free-field measurement at a distance
of 1 m
3) please contact Œrlikon Leybold Vacuum
4) CEI: 460 V / NEMA: 200 - 300 / 460 V
Description
Note
Summary of Contents for 10926
Page 36: ...36 GAET02307_002_10 06 2008 Œrlikon Leybold Vacuum fig 6 SV200 SV300 similar Spare parts ...
Page 38: ...38 GAET02307_002_10 06 2008 Œrlikon Leybold Vacuum Spare parts fig 7 SV200 SV300 similar ...
Page 40: ...40 GAET02307_002_10 06 2008 Œrlikon Leybold Vacuum fig 7 SV200 SV300 similar Spare parts ...
Page 42: ...42 GAET02307_002_10 06 2008 Œrlikon Leybold Vacuum ...