Technical data - Transport and unpacking
EN - 13
FIG. 5
1
FIG. 6
200 mm
1000 mm
DANGER
In case of two- and three-chamber ovens, each oven
shall be connected with a special knife switch, it is
not possible to connect more than one oven to one
knife switch.
3.3.b - Unipotential connection (Fig 5)
The equipment shall be inserted in a unipotential system,
whose effectiveness shall be veri
ed according to the
rules being in force.
A cascade connection shall be carried out among the
various oven components by using the screw (1) placed
on the rear oven side.
3.4 - OVEN POSITIONING (Fig 6)
DANGER
The oven SHALL NOT BE INSTALLED against
am-
mable walls such as furniture, partitioning walls,
matchboarding coatings, etc.... We recommend
to keep a safety distance of at least 20 cm from
the back of the oven. The pavement of the area in
which the oven is installed shall not be made of
ammable material.
• Position the oven on its
nal installation area following
the indications given in
gure 6, since they indicate
the minimum necessary distances as to have the oven
correctly functioning.
• Block the position of the oven applying the brakes
on the castors (optional) that are positioned on the
controls side.
3.5 - FIRST STARTING
DANGER
At the end of the installation and before turning the
oven on, carefully clean its internal part as indica-
ted in "Maintenance" chapter, checking for the pre-
sence any possible foreign or
ammable body.
• Turn the oven on as indicated in “Running” paragraph,
verifying that it correctly reaches the established tem-