51
Multi-functional DC inverter air/water heat pump
GB
Installation examples
3.2
DHW heating with solar energy:
C1 integrated circulation pump
C3 DHW circulation pump
E1 electrical booster heater for DHW
KW cold water inlet
T4 temp. sensor ambient air
T11 temp. sensor heating water return
T12 temp. sensor heating water fl ow
T13 temp. sensor DHW tank
Heat pump storage tank
enamelled with very large
heat exchanger surface
KW
DHW heating:
C1 integrated circulation pump
C3 DHW circulation pump
E1 electrical booster heater for DHW
KW cold water inlet
T4 temp. sensor ambient air
T11 temp. sensor heating water return
T12 temp. sensor heating water fl ow
T13 temp. sensor DHW tank
DHW tank enamelled
T13
C3
KW
E1
C1, T4, T11, T12
Space heating/Space cooling:
C1
integrated circulation pump
C2 in-house circulation pump
E2 electrical booster heater for heating
water
H2 underfl oor heating
T4 temp. sensor ambient air
T11 temp. sensor heating water return
T12 temp. sensor heating water fl ow
H2
E2
C2
C1, T4, T11, T12
C1, T4, T11, T12
C3
E1
T13
Buff er storage
tank for cold and
hot water