For the fi ve diff erent operating modes (see chapter 2 “System description“),
there is a variety of hydraulic integration options.
For the space-cooling modes, all water-carrying components must be insulated
impermeably and protected against corrosion.
The following application examples are only schematic diagrams. They must be
complemented by missing safety modules etc.
The safety-related equipment for DHW heating systems must be installed according to
DIN EN 12828.
In all systems the minimum volume fl ow in the heating circuit of the heat pump must be
adhered to. Non-observance can lead to failure.
Installation examples
3.2
Temperature
sensor
Fresh-water
circulation set
Heating circuit
set
Circulation
pump
Thermometer
Overfl ow valve
Mixing valve for
heating / change-
over valve
Pressure gauge
Diaphragm expan-
sion vessel
Filter/dirt
separator (with
magnet)
Vent valve
W
F
K
T*
M
U
W
F
K
T*
M
U
Safety valve
Underfl oor
heating /
radiator
Draining
Symbols and their meanings:
FZ
M
M
M
M
M
M
T
+
M
The heat pump is equipped with a wired electronic control unit.
The control unit is installed inside the house. In order to avoid interferences, the connection
cable of the control unit should not be laid close to the main connection line.
You can request a variety of information from the control unit. Furthermore, users and
technicians are provided with all setting options required.
The control unit is used during installation and maintenance.
Under normal circumstances, the control unit does not need to be accessible for residents.
OEG heat pumps are equipped with high-quality components to avoid and reduce sound
emissions. However, operating noise cannot be entirely avoided. Depending on the
installation location and pump model, the following minimum clearances towards sensitive
areas (e.g. bedroom windows) are recommended for the operation during the night.
Control unit
3.1.5
Recommended
installation distances
3.1.4
Minimum distance to heat pump
based on DIN 4109-1, 32nd BlmSchV and TA noise
Distance in meters, operating mode: night mode
Terrain type/
Installation position
Limit value
dB(A)
650001330
6 kW
650001331
9 kW
650001332
12 kW
650001333
18 kW
Industrial areas
70
1
1
1
1
Business parks
50
1
1
1
2
Core areas, village areas,
mixed areas
45
2
2
2
3
General residential areas,
small housing estates
40
3
4
4
5
All-residential areas
35
5
7
7
9
Spa areas, hospitals,
nursing homes
35
5
7
7
9