46
Inverter swimming pool heat pump
GB
The heat pump is compatible with all kinds of water treatment systems. However, it is
necessary that the treatment system (dosing pump for chlorine, pH, bromine and/or salt
chlorinator) is installed inside the hydraulic circuit downstream of the heating system.
For optimal operation and a long service life, the pH value of the water should always
be between 6.9 and 8.0.
Notes for detecting leaks when pressure testing:
To avoid the risk of fire or explosion, oxygen or dry air must never be used. Instead, use
dehydrated nitrogen or a mixture of nitrogen and refrigerant.
The low and high side test pressure must not exceed 42 bar.
Safety instructions
1.2
Water treatment
1.3
• OEG heat pump
• Two hydraulic water inlet/outlet connections (ø 50 mm)
• Installation and operating instructions
• Condensation draining kit
• Protective cover for the winter
• 4 vibration dampers (fastening material not included in the scope of delivery)
Scope of delivery