Document UT-MT-0573
Page 18 of 28
Edition 03/13/2012
Supersedes edition 02/09/2010
SLTH – SEMI-FLUSH THRESHOLD LIGHT
INSTRUCTION MANUAL FOR USE, INSTALLATION AND MAINTENANCE
10
/
Observing the circular level fixed on the jig, level the jig by operating the
three leveling lobe knobs (fig.11). If necessary, a weight may be placed
on the jig to hold the light base in position.
When the shallow base is in its final position, the conduit(s) must be
properly jointed to the hole(s) provided on the shallow base. This(these)
hole(s) can be provided either on the wall either on the bottom, the
number and the dimensions according to customer requirements
(fig.10).
The remainder of the space between the sides of the shallow base and
the drilled hole should be filled with sealer up to approx 25 mm from the
pavement, according to the local needs.
Fill the remaining 25 mm with a suitable joint sealing filler.
11
/
Lay the secondary power cable, equipped with a suitable two-pole
receptacle kit, and the grounding wire inside the cable duct.
12
To install the fixture place the O-Ring around the dome (fig.1 - n°19)
and between fixture and base (fig.7 - n°7); co nnect the plug and the
grounding wire of the fixture with the receptacle and the grounding wire
of the base; press the fixture by hand onto the base and secure it using
the six locking screws complete with washer, one drop of anaerobic
adhesive, medium type (e.g. Loctite 243), should be applied.
Tightening torque is 44 Nm.
ATTENTION: The fixture is subject to mechanical damage and/or
optical misalignment if not properly seated on the base flange.
Ø320
Ø320
Ø100
12.7
1
5
0
1
5
0
12.7
Figure 10 – 12” shallow base for side or bottom ducts (method “B”)