SLTH – SEMI-FLUSH THRESHOLD LIGHT 
INSTRUCTION MANUAL FOR USE, INSTALLATION AND MAINTENANCE

 

 

 

 
5.7.3.  Pressure test 
 
The assembly should be given a 1.38 kPa air pressure test. 
 
See par 4.3.3. 
 
 
5.8. 

VIBRATION-DAMPING BLOCK 

 
Remove the fixture from the base and open the fixture, as described at paragraph 4.1 
It is recommended to replace all the four vibration-damping blocks. 
Remove the lamp supporting plate (fig.1 – n°11) com plete with lamps, by unscrewing the 
four screws HSCH M5x25 (fig.1 - n°16). 
Remove the brass spacers and then the vibration-damping blocks.  
Mount the new vibration-damping blocks in their seats and insert the new brass spacers. 
Reassembly the lamp supporting plate, by tightening the four screws HSCH M5x25 (fig.1 - 
n°16); tightening torque is 2.5 Nm. 
Reassembly the fixture following instructions of par 4.2. 
 
 
5.9. 

PRESSURE VALVE 

 
If  a  leakage  is  found  through  the  pressure  valve  during  an  air  pressure  test,  check 
carefully  where  the  leakage  happens.  If  the  leakage  is  between  the  valve  (fig.5/6  –  n°7) 
and  the  lower  cover,  check  the  tightening  of  the  valve  body  to  the  lower  cover  from  the 
inside of the fixture. 
In  case  the  pressure  valve  needs  replacing,  operate  as  follows,  considering  the  fixture 
already  open,  as  described  at  paragraph  4.1.  Remove  the  valve cap. Unscrew the valve 
body with gasket from the inside of the lower cover by clamping the hexagonal end section 
of the valve body. Screw the new valve on the lower cover; tightening torque is 0.35 Nm. 
Check the valve core is tightened to the valve body and then screw its cap. 
Reassembly the fixture following instructions of par 4.2. 
 
 
5.10. 

CLEANING 

 
Service  life  depends  upon  the  entire  assembly  being  waterproof.  All  surfaces  must  be 
clean,  dry  and  free  of  all  foreign  matter  if  the  light  fixture  is  to  operate  for  an  extended 
period without requiring maintenance. 
 
NOTE: see par 5.0 for recommended spare parts list 
 

Summary of Contents for SLTH

Page 1: ...E AUTOMATIC KNOWLEDGE MANAGEMENT SYSTEM IT CAN BE SIGNED ON REQUEST THIS DOCUMENT AND THE DATA CONTAINED HERE IN IS PROPRIETARY PROPERTY AND SHALL NOT BE DUPLICATED USED OR DISCLOSED IN WHOLE OR IN PA...

Page 2: ...dition 02 09 2010 SLTH SEMI FLUSH THRESHOLD LIGHT INSTRUCTION MANUAL FOR USE INSTALLATION AND MAINTENANCE EDITION Data 02 09 2010 Emission 03 13 2012 Second Edition REVISIONS Index Date Description Wr...

Page 3: ...epaid by Purchaser to establish a claim under this warranty The cost of labour for the installation of a repaired or replaced Product shall be borne by Purchaser Replacement parts provided under the t...

Page 4: ...ystem and check for voltage presence before accessing REANIMATION The maintenance staff must be aware of the risks related to electricity criteria to prevent the risk of electric shock and resuscitati...

Page 5: ...RY WIRING 20 4 MAINTENANCE 20 4 1 REMOVING AND OPENING THE LIGHT UNIT FROM THE BASE 21 4 2 PRIMS CLEANING 21 4 2 1 Prism outside cleaning 21 4 2 2 Prism outside cleaning 21 4 3 PRISM REPLACEMENT 22 4...

Page 6: ...d Part List 9 Figure 2 Complete P N identification 10 Figure 3 Dome Outside view 11 Figure 4 Dome Inside view 11 Figure 5 Lower cover optional fuse cutout Inside view 12 Figure 6 Lower cover with opti...

Page 7: ...t through different positioning of the lamps In this way all lights result mechanically identical and the shallow base installation becomes very easy because no precise toe in is required during civil...

Page 8: ...er is provided with one threaded hole for cable entry and external grounding screw with yellow green cable lead size 2 5 mm 2 0 460 m long with male faston terminal A suitable valve is outside mounted...

Page 9: ...Vibration damping block 4 15 Spacer 4 16 HSCH M5x25 inox screw 4 17 5 inox grower washer 5 18 5x10x1 inox washer 7 19 O Ring 41150 silicone 1 20 O Ring 6850 silicone 1 21 Expanded PTFE strip 1 22 HSC...

Page 10: ...Basic P N Colour G Green A Green FAA Toe in RI Left LI Right ST Straight Lamps 200 2x105W 6 6A reflectorized Mounting Assembly B Standard Shallow Base 12 dia O No Mounting Assembly Options F Fuse Cut...

Page 11: ...nit fastening 3 Slot for dome removal 4 Painted area to identify the beam colour 5 Label with arrow for toe in identification Figure 3 Dome Outside view 1 Window to seat the prism 2 Through holes for...

Page 12: ...sulating strip cable 3 Insulating strips 4 Insulating strips fastening screws 5 Lamp supporting plate identification label 6 Leak test valve Figure 5 Lower cover optional fuse cutout Inside view 1 Cab...

Page 13: ...able entry The shallow base is designed for cementing in place by means of epoxy resin in a hole drilled in the pavement The fixture has to be fastened to the base by means of six hex cap screws compl...

Page 14: ...n the specified limits All surfaces of the recess must be clean and dry If any of these surfaces is damp it is desirable that it be dried and blown clean with a compressed air blast The recess side wa...

Page 15: ...15 of 28 Edition 03 13 2012 Supersedes edition 02 09 2010 SLTH SEMI FLUSH THRESHOLD LIGHT INSTRUCTION MANUAL FOR USE INSTALLATION AND MAINTENANCE Figure 8 Example of threshold configuration one trans...

Page 16: ...be laid in cable ducts fig 10 Proceed as follow to realize a proper installation A B 1 Unscrew the six locking screws and remove the fixture from the base using the lifting tool P N 332 4140 or 332 4...

Page 17: ...f sealer to the bottom of the drilled hole to assure a bond between the bottom of the light base and the drilled hole It may be necessary to place temporary plugs so as to block the wireways entrances...

Page 18: ...should be filled with sealer up to approx 25 mm from the pavement according to the local needs Fill the remaining 25 mm with a suitable joint sealing filler 11 Lay the secondary power cable equipped...

Page 19: ...NANCE 1 Positioning jig 2 Align the jig notch with the mark on the pavement 3 Circular level 4 Screws and spacers for the jig mounting 5 Lobe knob for positioning jig levelling 6 Shallow base notches...

Page 20: ...installation tightening torque is 25 Nm The fixture is subject to optical misalignment and or mechanical damage if not properly seated 4 3 SECONDARY WIRING The IEC 61823 International Standard AGL ser...

Page 21: ...screws HSCH M5x16 fig 1 n 22 If the lower cover assembly is hard to remove it is possible to use two of these screws in two threaded holes close to the locking holes Every time the fixture is removed...

Page 22: ...1 Removing the prism Remove the fixture from the base and open the fixture as described at paragraph 4 1 Clean out possible pieces of the old prism and all accumulated debris from the inside Remove t...

Page 23: ...fig 1 n 8 9 and fix it to the dome using the relevant screws BHC M5x10 fig 1 n 10 Inspect all components ins ide the fixture for damages or signs of corrosion Replace all necessary components Reassemb...

Page 24: ...et is dimensioned to allow the proper positioning when compressed between the mating surfaces Screws properly tightened are important in obtaining a complete seal TIGHTENING TORQUE lower cover HSCH M5...

Page 25: ...ctions of par 4 2 5 9 PRESSURE VALVE If a leakage is found through the pressure valve during an air pressure test check carefully where the leakage happens If the leakage is between the valve fig 5 6...

Page 26: ...dictated by the weather and the location of the fixtures 5 11 3 SNOWPLOW OPERATIONS Snowplow operators should exercise extra care not to strike the light fixtures with snowplow blades After snow remo...

Page 27: ...t once every three months or more frequently during the two four weeks following the reinstallation of a serviced fixture 5 11 6 LEAKAGE TEST If any fixture contains water remove the water and clean a...

Page 28: ...ten halogen 6 6 A with dichroic reflector 1 13 153 0040 Dichroic GREEN filter complete with holder for SLTH G 153 0070 Dichroic GREEN filter complete with holder for SLTH A 1 8 9 318 1130 Prism 1 3 32...

Reviews: