background image

 

Document UT-MT-0573 

 

Page 26 of 28 

Edition 03/13/2012 

Supersedes edition 02/09/2010 

 

 
SLTH – SEMI-FLUSH THRESHOLD LIGHT 
INSTRUCTION MANUAL FOR USE, INSTALLATION AND MAINTENANCE

 

 

 

5.11. 

MAINTENANCE PROGRAM 

 
In  order  to  ensure  maximum  light  fixture  life,  the  installed  units  should  be  subject  to  a 
maintenance  program  in  accordance  with  the  following  instructions  and  taking  as 
reference  the  Airport  Service  Manual  ICAO  -  Part  9  -  Airport  Maintenance  Practices  or 
FAA AC 150 5340-30. 
 
5.11.1.  DAILY OPERATIONAL CHECKS 
 
A daily operation check should be made of the fixture. The lights should be energized and 
visually inspected. If any lamps are out, the location of the fixture should be recorded and 
replaced at the time when the circuit is de-energized, as described at paragraph 4.1. 
 
 
5.11.2.  CLEANING 
 
Regular cleaning is necessary in order to ensure that in-pavement lighting fixtures operate 
at  maximum  efficiency.  The  prism  should  be  cleaned  periodically  as  per  paragraph  4.2. 
The regularity and type of cleaning will be dictated by the weather and the location of the 
fixtures. 
 
 
5.11.3.  SNOWPLOW OPERATIONS 
 
Snowplow  operators  should  exercise  extra  care  not  to  strike  the  light  fixtures  with 
snowplow  blades.  After  snow  removal  operations,  inspect  all  light  fixtures  to  locate  and 
replace, if necessary, any damaged light assemblies.  
Passes  over  the  light  rows  should  be  made  with  a  power  broom  only  if  practical. 
Whenever  snowplows  must  traverse  in-pavement  light  fixtures,  they  should  be  either 
travelling  at  less  than  10  km/h  or  have  the  blades  lifted  clear  of  the  fixtures. 
Recommended snow removal techniques are described in Airport Service Manual ICAO - 
Part 9 - Airport Maintenance Practices or FAA AC 150/5200-30. 
 
 
5.11.4.  MONTHLY INSPECTIONS 
 
This  fixture  is  designed  to  exclude  both  ground  and  surface  water  from  entering.  If  the 
lights  are  not  properly  maintained  (e.g.  screws  not  properly  tightened  and  O-Rings  or 
gaskets in bad condition) water may enter inside the fixture and create serious problems.  
To prevent this from occurring, it is recommended that each fixture be inspected from the 
presence of water at least once a month. More frequent inspection is desirable during and 
following rainy season. 
 
 
5.11.5.  SCREWS TIGHTNESS 
 

Summary of Contents for SLTH

Page 1: ...E AUTOMATIC KNOWLEDGE MANAGEMENT SYSTEM IT CAN BE SIGNED ON REQUEST THIS DOCUMENT AND THE DATA CONTAINED HERE IN IS PROPRIETARY PROPERTY AND SHALL NOT BE DUPLICATED USED OR DISCLOSED IN WHOLE OR IN PA...

Page 2: ...dition 02 09 2010 SLTH SEMI FLUSH THRESHOLD LIGHT INSTRUCTION MANUAL FOR USE INSTALLATION AND MAINTENANCE EDITION Data 02 09 2010 Emission 03 13 2012 Second Edition REVISIONS Index Date Description Wr...

Page 3: ...epaid by Purchaser to establish a claim under this warranty The cost of labour for the installation of a repaired or replaced Product shall be borne by Purchaser Replacement parts provided under the t...

Page 4: ...ystem and check for voltage presence before accessing REANIMATION The maintenance staff must be aware of the risks related to electricity criteria to prevent the risk of electric shock and resuscitati...

Page 5: ...RY WIRING 20 4 MAINTENANCE 20 4 1 REMOVING AND OPENING THE LIGHT UNIT FROM THE BASE 21 4 2 PRIMS CLEANING 21 4 2 1 Prism outside cleaning 21 4 2 2 Prism outside cleaning 21 4 3 PRISM REPLACEMENT 22 4...

Page 6: ...d Part List 9 Figure 2 Complete P N identification 10 Figure 3 Dome Outside view 11 Figure 4 Dome Inside view 11 Figure 5 Lower cover optional fuse cutout Inside view 12 Figure 6 Lower cover with opti...

Page 7: ...t through different positioning of the lamps In this way all lights result mechanically identical and the shallow base installation becomes very easy because no precise toe in is required during civil...

Page 8: ...er is provided with one threaded hole for cable entry and external grounding screw with yellow green cable lead size 2 5 mm 2 0 460 m long with male faston terminal A suitable valve is outside mounted...

Page 9: ...Vibration damping block 4 15 Spacer 4 16 HSCH M5x25 inox screw 4 17 5 inox grower washer 5 18 5x10x1 inox washer 7 19 O Ring 41150 silicone 1 20 O Ring 6850 silicone 1 21 Expanded PTFE strip 1 22 HSC...

Page 10: ...Basic P N Colour G Green A Green FAA Toe in RI Left LI Right ST Straight Lamps 200 2x105W 6 6A reflectorized Mounting Assembly B Standard Shallow Base 12 dia O No Mounting Assembly Options F Fuse Cut...

Page 11: ...nit fastening 3 Slot for dome removal 4 Painted area to identify the beam colour 5 Label with arrow for toe in identification Figure 3 Dome Outside view 1 Window to seat the prism 2 Through holes for...

Page 12: ...sulating strip cable 3 Insulating strips 4 Insulating strips fastening screws 5 Lamp supporting plate identification label 6 Leak test valve Figure 5 Lower cover optional fuse cutout Inside view 1 Cab...

Page 13: ...able entry The shallow base is designed for cementing in place by means of epoxy resin in a hole drilled in the pavement The fixture has to be fastened to the base by means of six hex cap screws compl...

Page 14: ...n the specified limits All surfaces of the recess must be clean and dry If any of these surfaces is damp it is desirable that it be dried and blown clean with a compressed air blast The recess side wa...

Page 15: ...15 of 28 Edition 03 13 2012 Supersedes edition 02 09 2010 SLTH SEMI FLUSH THRESHOLD LIGHT INSTRUCTION MANUAL FOR USE INSTALLATION AND MAINTENANCE Figure 8 Example of threshold configuration one trans...

Page 16: ...be laid in cable ducts fig 10 Proceed as follow to realize a proper installation A B 1 Unscrew the six locking screws and remove the fixture from the base using the lifting tool P N 332 4140 or 332 4...

Page 17: ...f sealer to the bottom of the drilled hole to assure a bond between the bottom of the light base and the drilled hole It may be necessary to place temporary plugs so as to block the wireways entrances...

Page 18: ...should be filled with sealer up to approx 25 mm from the pavement according to the local needs Fill the remaining 25 mm with a suitable joint sealing filler 11 Lay the secondary power cable equipped...

Page 19: ...NANCE 1 Positioning jig 2 Align the jig notch with the mark on the pavement 3 Circular level 4 Screws and spacers for the jig mounting 5 Lobe knob for positioning jig levelling 6 Shallow base notches...

Page 20: ...installation tightening torque is 25 Nm The fixture is subject to optical misalignment and or mechanical damage if not properly seated 4 3 SECONDARY WIRING The IEC 61823 International Standard AGL ser...

Page 21: ...screws HSCH M5x16 fig 1 n 22 If the lower cover assembly is hard to remove it is possible to use two of these screws in two threaded holes close to the locking holes Every time the fixture is removed...

Page 22: ...1 Removing the prism Remove the fixture from the base and open the fixture as described at paragraph 4 1 Clean out possible pieces of the old prism and all accumulated debris from the inside Remove t...

Page 23: ...fig 1 n 8 9 and fix it to the dome using the relevant screws BHC M5x10 fig 1 n 10 Inspect all components ins ide the fixture for damages or signs of corrosion Replace all necessary components Reassemb...

Page 24: ...et is dimensioned to allow the proper positioning when compressed between the mating surfaces Screws properly tightened are important in obtaining a complete seal TIGHTENING TORQUE lower cover HSCH M5...

Page 25: ...ctions of par 4 2 5 9 PRESSURE VALVE If a leakage is found through the pressure valve during an air pressure test check carefully where the leakage happens If the leakage is between the valve fig 5 6...

Page 26: ...dictated by the weather and the location of the fixtures 5 11 3 SNOWPLOW OPERATIONS Snowplow operators should exercise extra care not to strike the light fixtures with snowplow blades After snow remo...

Page 27: ...t once every three months or more frequently during the two four weeks following the reinstallation of a serviced fixture 5 11 6 LEAKAGE TEST If any fixture contains water remove the water and clean a...

Page 28: ...ten halogen 6 6 A with dichroic reflector 1 13 153 0040 Dichroic GREEN filter complete with holder for SLTH G 153 0070 Dichroic GREEN filter complete with holder for SLTH A 1 8 9 318 1130 Prism 1 3 32...