66
SET NORM SAFETY STOP information includes (Fig. 59):
> Graphic SAFE
> Symbols STOP and TIME.
> Safety Stop Time Set Point, flashing.
> Safety Stop Depth Set Point and symbol FT (or M).
Pressing and releasing the S button momentarily (< 2
seconds each time) will step through the Stop Time Set
Points of OFF, 3:00, and 5:00 (minutes:seconds).
Pressing and releasing the A button momentarily (< 2
seconds) will save the Stop Time setting and the Stop Depth
Set Point will flash, or if Stop Time is set OFF advance to
the SET CONS (Conservative Factor) screen with the Set
Point flashing.
Pressing and releasing the S button momentarily (< 2
seconds each time) will step through the Stop Depth Set
Points of 10, 15, and 20 FT (or 3, 4, 5, and 6 M).
Pressing and releasing the A button momentarily (< 2 sec)
will save the Safety Stop settings and/or advance to the
SET CONS screen with the Set Point flashing.
Pressing the A button momentarily and repeatedly (< 2
seconds) will step through the other SET U screens.
Depressing the A and S buttons simultaneously for 2
seconds will save the settings and revert back to the SET U
screen.
Fig. 59 - SET SAFETY STOP
Refer to page 106
for a description of
the No Decompres-
sion dive mode
Safety Stop feature.