42
When the 10 minute Surface Time has elapsed, the Local Default
Watch TIME screen (Main or Alternate Time) will replace the
Surface Mode display. The SURF MAIN screen can then be
accessed by pressing the M button for 2 seconds.
NORM SURF MAIN, information provided includes (Fig. 35):
> LINK symbol, if the Receiver is successfully Linked with a
Transmitter. (Note that this is the same icon used in Watch
Mode to signify that the Daily Alarm is set On.)
> Graphic NORM alternating with the Altitude Level graphic
SEA (or EL2 through EL13) and WET (if the unit is wet),
each On 3 seconds then 1/4 second blank.
> Battery icon if an ATOM Low Battery Warning Condition
exists, flashing if Too Low
> Tank Pressure and symbol PSI (or BAR), if the Receiver is
successfully Linked with an active Transmitter.
> Symbol DIVE and Number of that dive (0 if no dive has
been made yet).
> Symbols TIME and SURF, and Surface Interval Time
(hour:minutes) .
> NITROX symbol, if any GAS is set for a Nitrox dive.
> Tank 1 icon representing GAS 1, which is the default start
Gas and default Gas 10 minutes after a dive.
> Tissue Loading Bar Graph (TLBG), if any after a NORM or
FREE dive.
Fig. 35 - NORM SURF MAIN