141
An ON/OFF toggle is prevented when S is operated to
acknowledge/silence the Daily Alarm.
Press the L button to activate the Backlight.
Pressing the A button momentarily (< 2 sec), or depressing
the M button for 2 seconds, or if no button is pressed
during a period of 2 minutes, will revert the Display to the
FREE SURF MAIN screen.
Depressing the A and S buttons simultaneously for 2
seconds while viewing the CD Timer Status screen when the
CD Timer is OFF will access the SET CD TIMER screen with
the MINUTE Set Point flashing.
NOTES: Once the CD TIMER has been Set and
Started (by selecting ON), it will continue to run
in the background while on the surface until
turned OFF (stopped) or the Time reaches 0:00 at
which time the Alarm will strike (3 short beeps 3
times), the message TIMR will be displayed, and
the CD TIMER will revert to OFF.
Upon descending to 5 FT/1.5 M (i.e., entry into
FREE DIVE Mode), CD TIMER operation will con-
tinue, if in progress.
During a dive, the CD TIMER can be turned OFF
(stopped) and ON (started), but not Set.
R
E
S
P
O
N SIBLE
D
IV
E
R
Be a -
RESPONSIBLE
FREE DIVER
at all times.
The Set Point for the
Watch CDT does
not affect the FREE
CDT.