161
Inspection (continued) -
Closely examine the threads of the Battery Hatch(es) and
Housing(s) for any signs of damage that might prevent
proper threading.
Closely examine the inside of the Battery Compartment(s)
for any signs of corrosion indicating entrance of moisture
into the unit.
If corrosion is found, return the ATOM system to an
Authorized Oceanic Dealer, and DO NOT attempt to use it
until it has received factory service.
If moisture is found, it is best to have the unit inspected and
cleaned by an Authorized Oceanic Dealer.
If it is necessary to clean the Battery Compartment, flush it
and all components with a solution of 50% white vinegar
and 50% fresh water. Rinse with fresh water, and allow to
dry overnight, or blow dry with a hair dryer set at no heat.
ATOM (Watch) Battery Installation
Slide a new 3 volt type CR2430 Lithium Battery, negative
side down into the Battery Cavity. Slide it in from the Left
side (Fig. 148) and ensure that it slides under the contact
clip on the lower/right rim of the cavity.
Lightly lubricate the new Hatch O-ring with silicone grease
and place it on the inner rim of the Battery Hatch. Ensure
that it is evenly seated (Fig. 149).
Fig. 148 - ATOM BATTERY
INSTALLATION
Fig. 149 - ATOM BATTERY
HATCH O-RING