59
INFORMATION APPEARING IN THE RESULT COLUMN
Error types and other information are printed in the result column of the report. Check the transaction result in the result
column and take appropriate action if the result is an error.
Examples of messages that are printed in the result column
Message
Explanation
OK
The transaction was completed normally.
G3
Communication took place in G3 mode.
ECM
Communication took place in G3 ECM mode.
SG3
Communication took place in Super G3 mode.
FW.
The received data was forwarded.
NO RESPONSE
No response from the receiving party.
BUSY
Transmission was not possible because the other party was already using the line.
CANCEL
The transmission was cancelled while in progress.
MEMORY OVER
The memory became full during quick on-line transmission.
MEM.FULL
The memory became full during reception.
LENGTH OVER
The transmitted fax was over 1.5 m (59") long and therefore could not be received.
ORIGINAL ERROR
Direct transmission or manual transmission was not successful because a misfeed occurred.
PASS# NG
The connection was broken because the polling passcode was not correct.
NO RX POLL
The machine that was polled does not have a polling function.
RX POLL FAIL
The other machine refused the polling operation, or your machine broke the connection when
polled because no data was in memory.
NO F-CODE POLL
The other machine refused an F-code polling operation, or your machine broke the connection
when polled because no data was in its F-code memory polling box.
RX POLL# NG
The connection was broken because the sub-address for F-code polling memory was not valid.
F POLL PASS# NG
The connection was broken because the passcode for F-code polling memory was not valid.
BOX NO. NG
Your machine broke the connection because the specified sub-address for an F-code memory
box does not exist.
F PASS# NG
Your machine broke the connection because the other machine sent an incorrect passcode for
F-code communication.
RX NO F-CODE POLL
F-code polling was attempted, however, the other machine did not have an F-code polling
memory box.
NO F FUNC
F-code communication was attempted, however, the other machine does not support F-code
communication.
NO F-CODE
F-code communication was refused by the other machine because of an incorrect sub-address or
other reason.
M. BOX: [xxxxxx]
Data was received to a confidential or relay broadcast memory box, or data was sent from a
memory polling box.
The name of the memory box appears in [xxxxxx], and the type of F-code operation (relay request
reception, polling memory transmission, or confidential reception) appears in
.
NG xx (xxxx)
The communication handshake signals or image signals were distorted due to line conditions or
other reasons, and communication was not successful.
(1) First two digits of communication error number: Error code from 00 to 99.
(2) Last four digits of communication error number: Code for use by service technicians.
REJECTED
A fax was sent from a party from which reception is blocked.
(1)
(2)