G-46 MDB
P
ROGRAMMING
FUNCTIONS
35
National Rejectors, Inc. GmbH, Buxtehude
Setting the security stock per tube (Pro 26)
In the sub-functions 01 to 04 of Pro 26 you can set the number of coins not
to be paid out for each tube. Usually, the default is 3. For critical coins the
set value can also be higher. When paying out, only values from 1 to 9 are
considered.
In function Pro 0401 you can determine, that also the security stock
can be paid out.
For each tube a sub-function is assigned:
•
Left tube
Pro 2601
•
Middle/left tube
Pro 2602
•
Middle/right tube
Pro 2603
•
Right tube
Pro 2604
The coin changer is set at the manufacturer so that the security
stock is not sent to the vending machine control, if the machine
control questions the tube filling level
(real filling level = sent filling level + security stock).
Setting the wake-up time (Pro 53)
For coin changers in battery operation and with an external wake-up line a
time period can be set in function Pro 53, which specifies how long the coin
changer remains switched on after having received the last message from
the vending machine (wake-up time).
After the wake-up time had passed the coin changer is switched off
automatically and must be re-waked by the vending machine which activates
the external wake-up line.
There are factors (1–255) to be set, which are multiplied with a time unit of
0,264 seconds. If the setting is
≤
10 (= 2,6 seconds), a wake-up time of
30 seconds, set at the manufacturer, is applied.