P
ROGRAMMING
FUNCTIONS
G-46 MDB
34
National Rejectors, Inc. GmbH, Buxtehude
Setting the sensitivity of the string sensor (Pro 21)
This function is of special interest for validators with string sensor. With
function Pro 21 you can change the sensitivity of the sensor. The maximum
sensitivity is set by a value of 00. With a value >50 the sensor is only
activated, when the acceptance flap is opened by the string or the coin.
Setting the maximum coin number per tube (Pro 25)
In the sub-functions 01 to 04 of Pro 25 you can set the maximum number
of coins to be collected by each tube. When the programmed number of
coins is achieved for a tube, all following coins for this tube will be led into
the cash-box. Only when coins have been paid out from this tube, is the tube
able to collect coins again.
When "0" is programmed, coins will be sorted into the tube until the upper
filling level sensors indicate "tube full".
For each tube a sub-function is assigned:
•
Left tube
Pro 2501
•
Middle/left tube
Pro 2502
•
Middle/right tube
Pro 2503
•
Right tube
Pro 2504