Remedying faults
Solving actual problems
Problem
coin validator rejects all
coins
coin validator rejects single
coins
coins fall into cash-box and
not into tubes
motor default
Cause
inhibition active
coin channel inhibited
coins emptied without
inventory before transport
coin counters was not set to
zero before filling the tubes
payout slide blocked by coin
flat cable between payout slide
and power supply unit not
connected
defective flat cable between
payout slide and power supply
unit
sensor for final motor position
defective
motor control of power pack
pcb defective
Remedy
if necessary, refill machine
if necessary, clear expendable
material (e.g. coffee filter)
check Pro 15 and DIL switch
and enable inhibited channel
Read out error message via
setting module (see section
after next)
check filling levels and set
display to zero
reset coin counters
remove jammed coins, carry
out test by means of internal
keyboard
connect flat cable
exchange payout set
(see chap. 12)
exchange payout set
(see chap. 12)
exchange power pack pcb