G-46 MDB
P
ROGRAMMING
FUNCTIONS
29
National Rejectors, Inc. GmbH, Buxtehude
8
Programming functions
Structure of the PRO functions
Function
Meaning of the adjusted value
0401
Operation mode 1
00000000
Adding up credit which cannot be displayed (1),
reset credit (0)
Disable internal keyboard
(release via machine control) (1),
enable keyboard (0)
Security stock in tubes can be paid out with DISPENSE
(1)
0404
Operation mode 3
00000000
While filling the tubes, only accept coin to be sorted
into tubes (1)
reserved
Transmit tube filling level incl. security stock to the machine
(1)
Not enable inventory keys via the machine control (1)
1501
Individual inhibiting of channels 1–8 (1)
00000000 channels 1–8 (right to left)
8
1
1502
Individual inhibiting of channels 9–16 (1)
00000000 channels 9–16 (right to left)
16
9
2101
Sensitivity of the string sensor
2501
Maximum number of coins in left tube
2502
Maximum number of coins in middle/left tube
2503
Maximum number of coins in middle/right tube
2504
Maximum number of coins in right tube