Manual G-26.4000:
Page 57
National Rejectors, Inc. GmbH, Germany
Display
Meaning
01
Left motor not in final position
02
Middle motor not in final position
03
Right motor not in final position
04
Left and right motor not in final position
05
Right and middle motor not in final position
06
Left and middle motor not in final position
07
Left, middle and right motor not in final position
When a motor fault occurs during payout, subsequent payout operations are made with the two other
tubes.
Simultaneously,acceptance of high valued coins is inhibited (function 17, only when ‘Inhibit of high
valued coins’ is selected in function 04). The LED for ‘tube empty’ lights up.
The fault is stored within the error memory and is displayed temporarily.
Pressing any key the last fault is displayed.
Either:
o It is a fault, which can be removed by yourself, for instance a jammed coin
G-26.4000 Standard, G-26.4800 Professional:
* Remove jammed coin
* Key ‘F’
o Fault number appears on display
* Key ‘F’
G-26.4800 BDV-Standard:
* Remove jammed coin
* Execute inventory function by vending machine
The fault is removed.
All tubes pay out coins correctly.