background image

Manual G-26.4000:

Page 19

National Rejectors, Inc. GmbH, Germany

8. Display of Line Conditions

G-26.4000 Standard
 (Remedying faults within vending machine)

o Changer in standby

* Key ‘+’

* Key ‘P’

o On display appears for example:

Where:

0060

= price 60 p

01

= selection line 1 active

The price of the selected product appears also on the external display. If another product is selected
the display shuts down temporary so that even if the price is the same the change to another selection
line is displayed.

For line conditions following displays are possible:

-6 = line 6 active (coin inhibit)
-8 = line 8 active (reset)
-9 = line 9 active (tube empty)
01 = selection line 1 active
.
.
06 = selection line 6 active
.
.
10 = selection line 10 active

* Key ‘P’

o Changer returns to standby

Display of Line Conditions

Summary of Contents for G-26.4000 Series

Page 1: ...Manual for Changer Series G 26 4000 National Rejectors Inc GmbH Zum Fruchthof 6 D 21614 Buxtehude Telefon 04161 70 75 0 Telefax 04161 70 75 55 02 94 vBi Edition 10 0 HB 2640 GB Technical Documentation ...

Page 2: ...mination coins accepted including up to 3 tokens Economicalauditing o Record of sales machine data o Data printout o Data display o Readout of data by a data retrieval unit Security o Reliable validation o Low power consumption 10 prices G 26 4000 Standard o Quick simple price changing Fast servicing o Simple modular construction Ready for new market requirements o Re programmable validator change...

Page 3: ...06 32 Vend Sales Data 08 33 Vend Sales Data per Price Line 10 34 Coin and Tube Data 12 35 Diagnostics 13 36 Setting Time and Date 14 38 Single Coin Inhibit 15 40 Printout Format 16 42 Coins to be inhibited 17 47 Communication with Audit Unit 18 49 Communication with a Card System 19 50 Communication with a Bill Validator 20 51 Communication with a Talking Module 21 52 Setting of tube empty conditi...

Page 4: ...ns up to 30 mm diameter left tube coins up to 26 5 mm diameter middletube coins up to 23 5 mm diameter The tubes may store the same denomination coin to increase capacity The validator and changer each have their own microprocessor Both processors communicate via a serialinterface Using a P C the validator is self teaching enabling reprogramming of coin acceptance It is possible to use a card syst...

Page 5: ...he values set with function 3 4 15 17 and 19 can be overwrittenbythevendingmachinecontrol Thusitispreferabletosetthesefunctionsbythevending machine control Differences Professional BDV Standard externaldisplay connectable yes no keyboard with internal display existing option printout of data readout with data retrieval possible not possible unit functions adjustableby adjustableby keyboard or vend...

Page 6: ...g Temperature Operation 0 C 55 C Ambient temperature of the unit Storage 30 C 75 C Humidity Maximum90 Component spec DIN 40 040 KSF Power supply 115 230 Volts European Standard 110 220 V A C 120 240 V A C 24 V A C and 24 V D C Power consumption 5 VA standby 20 VA max Switching For A C current max 240 Volts 2 5 A 600 VA For D C current max 24 Volts 50 mA short circuit Noiseimmunity According IEC 80...

Page 7: ...of the 6 parameters The validator checks whether this value lie within its programmed limits i e within the coin channel Within each channel the limit values for one coin denomination can be set The 12 coin channels of the G 10 4000 5enablesthecoinacceptanceofamaximumof12differentcoindenominations This means coins whose characteristics correspond Thus this also refers to tokens Based on this there...

Page 8: ... however they have the same coin values Example I Label of a G 10 4000 5 with German coin acceptance This example shows the the coin channels 3 and 10 4 and 11 as well as 5 and 12 are linked together The abbreviation E markes the channels with narrow bandwidth So for the same coin denomination two channels are programmed one with normal and the other with narrow bandwidth Example II Linked channel...

Page 9: ... Example Programmed coin value within channel 5 narrow bandwidth 1 00 Programmed coin value within channel 12 1 00 Due to the fact that channel 5 and 12 are linked together if the coin acceptance is inhibited within channel 5 channel 12 is also inhibited In order to inhibit the coin acceptance of channels 9 to 12 a 4 pole Dual In Line switch is provided on the pc board of the G 10 4000 5 see figur...

Page 10: ...s considerably the sorting security Switch 1 in the lower position of the 4 pole Dual In Line switch has two functions By using this switch you can activate the sorting function see page 11 By moving the appropriate switch in the upper position open the channel is inhibited By using the individual coin inhibit of channels 9 to 12 it is possible for instance to increase the slug rejection by inhibi...

Page 11: ... sorting function special function for validators with English coin acceptance can be activated by using switch 1 if within channel 12 no coin is programmed if the coin denomination accepted by channel 9 is guided into the right tube Move switch 1 on the 4 pole Dual In Line switch in the upper position o Now coins accepted within channel 9 are no longer guided into the right tube but coins accepte...

Page 12: ...of an inserted coin programme the coin channels by inserting special coins change the validator setting in order to adapt it to the desired vending machine A programming station for the G 10 4000 5 includes the following units G 55 0287 adapter for AT computers with 9 pin plug or G 55 288 adapter for XT computers with 25 pin plug G 19 0577 tester G 19 0584 test stand 93 00 631 software KUNEMP deli...

Page 13: ... Prior to installation Check that changer is correct for your machine Check operating voltage and change if necessary switch S1 on interface module Only units for 110 240 Volts Installation o Connecting cable to vendor must not yet be plugged Mount changer Unfasten safety screw see figure Remove validator Secure changer with screws Refitvalidator Fix safety screw Connect non fused green yellow ear...

Page 14: ...hibited once acceptance limit is reached o Change limit maintains change store 0302 Limitedchangegiven Only effective within mode multi vend o Setting of tokens Setting value of up to three 0303 different tokens possible o Single vend Coins inserted for each vend 04 Changerinhibitscoin Change given after each vend acceptance when credit exceeds automatically highest price o Multi vend More than on...

Page 15: ...exact change Customer can buy however he lights up unchangeable possibly has to renounce his residual money Money which cannot be paid back will remain as credit Note o The exact change lamp now solely depends on the tube empty condition set on function 22 o When coins are still in the tubes they are paid out even in case of tube empty display o Residual credit due to insufficient change remains o...

Page 16: ... cup 0401 is used o Data display Audit purposes vending machine data 05 sales data 06 vend sales data 08 09 vend sales data per price line G 26 4000 Standard 10 11 coin and tube data 12 o Diagnostics Servicing 13 o Time date setting 14 o Single coin inhibit Any coin may be inhibited 15 o Printout format Short or full data 16 o Coins to be inhibited Applicable during tube empty 17 condition functio...

Page 17: ...Check operating modes are correctly set function 04 Check that motors are in standby state key twice Fill each tube with at least 20 coins see Filling Change Tubes page 18 Check setting of time and date function 14 Set prices G 26 4000 Standard and machine number function 02 Check maximum change and credit function 03 When tokens are accepted check correct setting function 0303 Check single coin i...

Page 18: ...of tubes I I not empty full II empty Note Before starting to fill tubes cashbox should be emptied as coins guided into cashbox are not counted Even when keyboard is blocked filling of change tubes by pressing key is possible Inserted coins will be audited All coins are accepted including the coins inhibited by function 15 Additionally it is possible to fill tubes using function 1305 see Diagnostic...

Page 19: ...he selected product appears also on the external display If another product is selected the display shuts down temporary so that even if the price is the same the change to another selection lineisdisplayed For line conditions following displays are possible 6 line 6 active coin inhibit 8 line 8 active reset 9 line 9 active tube empty 01 selection line 1 active 06 selection line 6 active 10 select...

Page 20: ...en the vending machine has finished the vend the following display is obtained If no further test vend is initiated the display shows again the status indication for test vends first figure on this page after 10 seconds After approximately 40 seconds the changer returns to standby The number of test vends is counted and can be displayed within function 08 vend data under 0903 Also the printout inc...

Page 21: ...r switch on CPU pc board protected left or upper plug position Note UnitswithamodelnumberhigherthanG 26 4000 4haveanadditionalswitchontheinterface module This switch must be in position keyboard enabled When keyboard is blocked the following functions are possible function 01 inventory ReferringtotheG 26 4800Professionalthisfunctioncanbeinhibitedbythevendingmachine Thus function 01 can only be exe...

Page 22: ...les data 06 E salesdata F P or vend data 08 E vendtotals E vendsubtotals F P or sales vends per price 10 E salesperprice E vends per price F P or coin and tube data 12 E coin tube data F P or diagnostics 13 F P or setting time and date 14 E time date F P or single coin inhibit 15 F P or printout format 16 F P or coins to be inhibited 17 F P or communication with audit unit 18 F P or communication ...

Page 23: ... function F 01 Inventory left tube E 01 I Payout coins singly E once Payout coins rapidly E continuously Inventory middle tube F 01 I Payout coins singly E once Payout coins rapidly E continuously Inventory right tube F 01 I Payout coins singly E once Payout coins rapidly E continuously Return to base function F 01 Return to standby P or shuts down ...

Page 24: ...y 0201 coin value 00 30 Rapid increase 100 times E 0201 lowest coin value 05 30 Setting lower price E and simultaneously until 00 00 appears then set price Programming or price P 0202 00 10 After display of price 10 Note The machine number cannot be changed if a data retrieval unit is used Displaymachinenumber P 02AU 001234 Change machine number 1 02AU 001235 Change machine number 100 E 02AU 00133...

Page 25: ...t be changed if a data retrieval unit is used Action Key Display Select function F until 02 02 appears 000000 Displaymachinenumber P 02AU 001234 Change machine number 1 02AU 001235 Change machine number 100 E 02AU 001335 Setting of 5th and 6th digit E until desired 02AU number appears 101335 Return to base function P 02AU Return to standby P shuts down MachineNo ...

Page 26: ...est coin value 01 00 Rapid increase 100 times E 0301 lowest coin value 06 00 Displaychangelimit P 0302 00 00 Increase by lowest coin once 0302 value 00 01 Increase by multiple of continuously 0302 lowest coin value 00 50 Rapid increase 100 times E 0302 lowest coin value 01 50 Reduce to lower amount E and simultaneously until 00 00 appears then to setting required Note If the acceptance and change ...

Page 27: ...ly 0303 lowest coin value 00 40 Rapid increase 100 times E 0303 lowest coin value 05 40 Display of set token 2 P 0304 01 00 Changes as described above Display of set token 3 P 0305 02 00 Changes as described above Return to base function P 03 Return to standby P or shuts down Note For each vend only one token is accepted i e after insertion of a token the unit goes automatically into mode committe...

Page 28: ...ears Display of setting E 04 see next page 10000100 Select digit to be changed Psequentially 04 10000100 Change setting 04 11000100 Programme new setting P 04 11000100 Display of next setting F 0401 G 26 40000 Standard 00000000 Change setting as described above Return to base function F 0401 Return to standby P or shuts down OperatingModes ...

Page 29: ...000 Standard not yet used 1 Blocking of coins when tube empty unchangeable 1 Exact change lamp lights up unchangeable 1 reset line 6 0 reset line 8 1 external reset 0 internal reset 1 committed to vend 0 uncommitted to vend 1 single vend 0 multi vend OperatingModes G 26 4000 Standard G 26 4000 Standard ...

Page 30: ...r to payout of residual money in single vend the existing residual credit is displayed for approximately 2 5 seconds Then payout starts Delayed reset After reset price line remains active for approximately 300 msec Cigarette mode If the value in the validator is 0 it is possible to select a time of 4 seconds by setting the fourth digit to 1 However if a time of 0 is programmed in the validator the...

Page 31: ...ng Machine Data Action Key Display Select function F until 05 05 appears Displayidentification E 0501 number 1335 Display audit number E 0502 with this identification no 0120 Displayinterruptions E 0503 to supply 0001 since last printout Return to base function F 05 Return to standby P or shuts down ...

Page 32: ...5 75 Actual level left tube value E 0604 3 45 Actual level middle tube value E 0605 12 80 Actual level right tube value E 0606 5 20 Since last printout Left tube inventories E 0607 3 20 Middle tube inventories E 0608 11 80 Right tube inventories E 0609 5 70 Credit to GLOBO card E 0610 43 00 Receipts from E 0611 billvalidator 30 00 Erased residual credit E 0612 00 19 Return to base function F 06 Re...

Page 33: ...vends E 0901 10 Since last printout Total sales E 0802 3 50 Total vends E 0902 3 Display of number of E 0903 free vends 2 Return to base function F 08 if a GLOBO Card system is connected Total sales with GLOBO Card E 4 times 0804 55 00 Number of vends with E 0904 GLOBO Card 75 Discount by GLOBO E 0805 Card System 12 50 Return to base function F 08 Return to standby F shuts down Vend Sales Data ...

Page 34: ...Line G 26 4000 Standard Action Key Display Select function F until 10 10 appears Sales per price line Esequentially 1008 to required price 09 30 Vends per price line Esequentially 1108 to required price 930 Return to base function F 10 Return to standby P or shuts down Vend Sales Data per Price Line ...

Page 35: ...oins in right tube quantity E 1203 14 Since last printout Coins accepted in left tube E 1204 165 Coins accepted in middle tube E 1205 298 Coins accepted in right tube E 1206 119 Number of accepted coins E 1207 coin 1 305 Number of accepted coins E 1208 coin 2 114 Number of accepted coins E 1209 coin 3 98 Number of accepted coins E 1214 coin 8 0 Return to base function F 12 Return to standby P or s...

Page 36: ... to E 1301 service state Execute see Remedying E 1301 Faults Select Motors to E 1302 standby state Execute see Remedying E 1302 Faults Select Take over P 1303 data block Access to data block E 1303 2 50 Either Take over data block 1303 and erase credit 00 00 or Take over data block P 1303 and retain credit 2 50 Function 13 continued next page Diagnostics ...

Page 37: ...w insert coins to fill tubes Inserted coins are counted but not evaluated as credit Select Display of line P 1306 conditions G 26 4000 Standard Execute E 1306 Example vend line 1 active 01 Return to base function F 13 Return to standby F shuts down Example of printout Reserve Byte Language of Printout Machine Type Cigarette Mode Lowest Coin Denomination 000130000010 001000500100 left tube middle t...

Page 38: ...Display Select function F until 14 14 appears Time and date E 1306 example 92114830 13 06 92 date 11 48 30 time Select digit to be Psequentially 1306 changed 92114830 Changedigit 1306 92124830 Programme digit P 1306 92124830 Return to base function F 14 Return to standby F shuts down Setting Time and Date ...

Page 39: ...26 4000 Page 39 National Rejectors Inc GmbH Germany Function 14 Setting Time and Date day month year hours minutes seconds Seconds unit can only be set to zero Flashing digit may be changed Setting Time and Date ...

Page 40: ...it Action Key Display Select function F until 15 15 appears Display of setting E 15 see next page 0101000 Select digit to be P sequentially 15 changed 0101000 Change digit 15 0100000 Programme change P 15 0100000 Return to base function F 15 Return to standby F shuts down Single Coin Inhibit ...

Page 41: ... Rejectors Inc GmbH Germany Function 15 Single Coin Inhibit coin 8th channel coin 2nd channel 0 coin accepted 1 coin inhibited Acceptance of lowest denomination coin cannot be inhibited Flashing digit may be changed Single Coin Inhibit ...

Page 42: ... of setting E 16 see next page 0000 Select digit to be P 16 changed 0000 Change digit 16 0001 Programme change P 16 0001 Return to base function F 16 Return to standby P or shuts down Printout Connect printer Press PRINT key In the case of a fault condition printout is possible even whilst on the internal display four points are flashing Printout Format ...

Page 43: ...ed 1 Vend sales data per price line is not printed 0 Time is printed 1 Time is not printed 0 Audit data is erased after printout 1 Audit data is only erased after initialization with a data retrieval unit for service see chapter 19 This digit cannot be changed by the keyboard After readout with a data retrieval unit the digit is set to 1 whilst it is set to 0 after initialization with a data retri...

Page 44: ...S 20 0 number of test sales This section is CASHLESSCARD printed out only SALES 0 00 turnover using GLOBO CARD if a card system CYCLES is operating 0 number of vends using GLOBO CARD DISCOUNT 0 00 CASH TO CARD credit to cards reloading 0 00 cards SALES VENDS S1 0 20 C1 2 S2 3 00 C2 6 S3 5 00 C3 5 S4 14 00 C4 7 Discountby S5 0 00 ecological C5 0 function S6 0 00 C6 0 S7 0 00 C7 0 S8 0 00 C8 0 S9 0 ...

Page 45: ...t printed 0 1 0 Time is printed 1 Time is not printed 0 Audit data is erased after printout 1 Audit data is only erased after initialization by a data retrieval unit for service see chapter 19 This digit cannot be changed by the keyboard After readout with a data retrieval unit the digit is set to 1 whilst it is set to 0 after initialization with a data retrieval unit for service noinfluence Print...

Page 46: ...customers to tubes 10 00 money inserted during tube filling operator CHANGE 15 60 change paid out 11 50 money paid out during inventory 0 00 erased remaining credit TUBE STORE 16 70 SALES 24 30 CYCLES 20 0 number of test sales This section is CASHLESSCARD printed out only SALES 0 00 turnover using GLOBO CARD if a card system CYCLES is operating 0 number of vends using GLOBO CARD DISCOUNT 0 00 CASH...

Page 47: ...ited when the tube empty condition applies The tube empty condition is set on function 22 Action Key Display Select function F until 17 17 appears Display setting E 17 see next page 1111000 Select digit to be P sequentially 17 changed 1111000 Change digit 17 1110000 Programme change P 17 1110000 Return to base function F 17 Return to standby P or shuts down ...

Page 48: ...National Rejectors Inc GmbH Germany Function 17 Coins to be inhibited coin 8th channel coin 2nd channel Acceptance of lowest denomination coin 1st channel cannot be inhibited Flashing digit may be changed Coins to be inhibited ...

Page 49: ...sional Attention A 1 may only be programmed if an audit unit is available Action Key Display Select function F until 18 18 appears Display of setting E 18 0 Change digit 18 1 Return to base function P 18 Programme change P or shuts down Note 0 no audit unit available 1 connected with audit unit The fault code 32 appears if audit unit switched off vendor cable possibly is defective no audit unit co...

Page 50: ...0 Change setting 19 1 Return to base function P 19 Programme new setting P or shuts down Note 0 no card system available 1 card system connected The fault code 33 appears if the card system is switched off the connecting cable is defective no card system is available however a 1 is programmed The display shuts down after approximately 2 minutes The changer no longer attemps to communicate with the...

Page 51: ...ting 20 1 Return to base function P 20 Programme new setting P shuts down Note 0 no bill validator available 1 a bill validator is connected The fault code 34 appears if the bill validator is switched off the connecting cable is defective no bill validator is available however a 1 is programmed The display shuts down after approximately 2 minutes The changer no longer attemps to communicate with t...

Page 52: ...0 Standard and G 26 4800 Professional Attention A 1 may only be programmed if a talking module is connected to the changer Action Key Display Select function F until 21 21 appears Display setting E 21 0 Change setting 21 1 Return to base function P 21 Programme new setting P or shuts down Communication Talking Module ...

Page 53: ...ssibletodeterminethetubeconditionwhichwillcausethedisplay of tube empty and to inhibit the acceptance of all coins programmed by function 17 Please refer also to function 17 Coins to be inhibited Action Key Display Select function F until 22 22 appears Display setting E 22 00 Increase by 1 22 01 Return to base function F 22 Return to standby P or shuts down Setting Tube empty condition ...

Page 54: ... fulfilled when either the tube for the lowest coin value is empty or both tubes for the higher coin values are empty Value to be set Tube empty condition 00 A empty or B and C empty 01 all tubes empty 02 A and B empty 03 A and B empty or A and C empty 04 only A empty 05 A empty or B empty 06 A empty or B empty or C empty 07 A and C empty 08 A empty or C empty 09 B and C empty 10 only B empty 11 B...

Page 55: ...32 no answer from audit unit 1 33 no answer from credit card system 2 34 no answer from bill validator 2 41 file transfer caused by vending machine control 3 42 file transfer caused by audit unit 3 43 file transfer caused by credit card system 3 44 file transfer caused by bill validator 3 47 file transfer caused by talking module 3 48 file transfer caused by changer 3 51 vend operation 3 52 termin...

Page 56: ...l 1 left tube accepted 3 2 I coin channel 2 middle tube accepted 3 3 I coin channel 3 right tube accepted 3 4 coin channel 4 cashbox accepted 3 1 return lever depressed 3 Categories Category 1 These faults result in a service case and a shutdown of the vendor Category 2 These faults result in a service case however further operation of vendor is possible with reservation Category 3 Status indicati...

Page 57: ...ith the two other tubes Simultaneously acceptance of high valued coins is inhibited function 17 only when Inhibit of high valued coins is selected in function 04 The LED for tube empty lights up The fault is stored within the error memory and is displayed temporarily Pressing any key the last fault is displayed Either o It is a fault which can be removed by yourself for instance a jammed coin G 26...

Page 58: ...To ensure that no customer gets less change due to the defective motor initiate one payout operation function 01 inventory from the tube with the defective motor o The fault number appears temporarily on the display Thechangerremainsinworkingcondition Whenchangeisgiventhetubewithdefectivemotorisnot operated The acceptance of high valued coins is inhibited function 17 and the LED tube empty lights ...

Page 59: ...4 15 16 and 17 Display Meaning Four points are flashing every two seconds This means that the connecting cable to the validator or the validator itself is defective The fault condition can be removed as follows Check whether the plug of cable to validator is plugged in correctly Check whether the cable strands are fixed and possibly change cable Check whether validator is defective and possibly re...

Page 60: ...f functions 2 3 4 15 16 and 17 Block keyboard again Display Meaning 21 Price data is sent to validator 22 Price data is loaded from validator 23 Data block is loaded into validator 1 I Coin channel 1 left tube accepted 2 I Coin channel 2 middle tube accepted 3 I Coin channel 3 right tube accepted 4 Coin channel 4 cash box accepted 1 Return lever depressed In case the above mentioned numbers are di...

Page 61: ...l unit connected however a 1 is programmed within the appropriate function If the fault codes 33 or 34 appear it is possible to change functions 19 or 20 in spite of a blocked keyboard This is necessary if it is not possible to replace the unit immediately Afterapproximately2minutesthedisplayshutsdown Thechangernolongerattempstocommunicate with the card system or the bill validator respectively Th...

Page 62: ...thin the error memory and here 04 corresponds to the number of faults 03 is the code of the fault Display prior fault S 01 03 01 03 is the number of fault within the error memory 01 is the code of the fault Return to standby F or P shuts down Function S02 Erasing of error list What Key Display Select service function E S 01 Select function erase F S 02 Erase error list E S 02 S 02 E S 02 Service F...

Page 63: ...rating instructions GLOBO Card System Installation Function S04 Tube counter set to Zero What Key Display Servicefunction E S 01 Select function Erase F until S 04 appears S 04 Set tube counter to zero E S 04 S 04 S 04 o The tube counter is erased and the display shuts down after approximately one second Function S03 Initialize GLOBO Card system Service Functions ...

Page 64: ...omination see function 0303 and operating instructions for KUNEMP G 10 4000 5 Filling change tubes through validator either with key or by function 1305 see item Filling Change Tubes page 18 Check and replace if necessary coin damper in validator Clean validator as follows o No dismantling necessary Open front of validator by turning lock knob to the left Clean with damp cloth o Keep unit away fro...

Page 65: ...ew Remove validator Remove screws 1 and 2 Withdraw module Fit new module Replace screws 1 and 2 Refit validator and fasten safety screw Interface modules available 4 and 10 price outputs for 110 120 220 240 Volts A C switchable 110 220 and 120 240 Volts 4 and 10 price outputs for 24 Volts A C 4 price outputs for 24 Volts A C COCA COLA Standard G 26 4500 SIMPLEX III G 26 4400 SIMPLEX V G 26 4800 Pr...

Page 66: ...ement of connecting cable Unfasten safety screw Remove cable clamp two screws of the interface module Remove cable Refit and secure new cable Pay attention that the cable clamp covers the shield Refit validator and secure with safety screw Replacement connecting cable ...

Page 67: ...he converter enables connection of one of the following types of bill validators ARDAC S 2000 Armatic AL 07 Coges LMB 1 LMB 8 Landis Gyr BSN 40 The blocking signal of this unit must be high active If you would use another type of bill validator please contact NRI For each type of bill validator a special connecting cable is required which can be ordered at NRI Please refer also to the separate ope...

Page 68: ...changercanbeloadedintoapersonalcomputerforfurther processing There exist three different types of data retrieval unit data retrieval unit for service data retrieval unit for driver data retrieval unit for management After printout of data by a printer the data is erased However if prior to printout a data retrieval unit was used the data remain stored even after printout Only after initialization ...

Page 69: ...imensions the talking module can be used in all kinds of vending machines The use of IC s of state of the art technology enables a natural voice reproduction By using a personal computer you can create individual text yourself Please refer to the separate Operating Instructions for Talking Module G 58 0100 Talking Module ...

Page 70: ...Manual G 26 4000 Page 70 National Rejectors Inc GmbH Germany Return lever Label Display Max Fillinglevel Keyboard Drawing Changer ...

Page 71: ...nualfor ChangerSeriesG 26 4000 Appendix Index TechnicalInformation3 93 LatestProgrammeVersion TechnicalInformation5 93 ChangerSeriesG 26 4000 6 ManualG 26 4000 Appendix National Rejectors Inc GmbH Germany ...

Page 72: ...anger software offers the following functions 1 Function 19 Activate communication with the NRI card system GLOBO Card 2 Function 03 Setting of a subsidy instead of token no 2 3 Function 04 Erase remaining credit 4 Function 04 Activate price table within G 26 4000 Simplex V 5 Function 02 Setting of prices within G 26 4000 Simplex V 6 Function 10 Read out of vend sales data via display G 26 4000 Pr...

Page 73: ...on with NRI card system GLOBO Card Action Key Display Select function F until 19 appears 19 Displaysetting E 19 0000 See page 3 Select digit if required P twice 19 0000 Change setting if required 19 0010 Select last digit P 19 0010 Change this setting 19 0011 Return to base function F 19 Return to standby P or shuts down ...

Page 74: ...working with the protocol BDV 001 the machine controller can sometimes automatically set the last digit of the display described above to 0 after switching on the machine If a card system is connected it does not work However it is possible to put it into operation in the following way Set the 2nd digit from the right to 1 last digit can only be modified via the changer keyboard 4th digit from the...

Page 75: ...e sure that within function 19 the communication with the Globo card system as well as subsidies are activated refer to page 2 Action Key Display Select function 03 F until 03 appears 03 Displayacceptancelimit E 0301 00 00 Select function 03 04 P three times 0304 00 05 Increase by lowest coin once 0304 value 00 10 Increase by multiple of continuously 0304 lowest coin value 00 50 Rapidincrease cont...

Page 76: ...ing the return lever All erased credit amounts are added by the changer control and printed out under erased residual credit when printing the audit data When programming this function please refer to the Manual for Changer Series G 26 4000 function 04 1 Price setting with Simplex V 1 Exact change lamp lights up unchangeable 1 Committed to vend 0 Uncommitted to vend 1 External reset 0 Internal res...

Page 77: ...o set the prices within the G 26 4000 Simplex V Thus the audit data for the G 26 4000 Simplex V now include also the information referring vend sales per price line Prior to price setting it is necessary to activate the price table within the G 26 4000 Simplex V G 26 4000 Standard Only valid for G 26 4000 Simplex V G 26 4000 Standard When programming this function please refer to the Manual for Ch...

Page 78: ... sure that the price information within the machine control is adapted Price setting within the machine control depends on the lowest coin value in the changer If the G 26 4000 Simplex V has a price table the 1st price within the machine control has to correspond with the lowest coin value of the changer All other prices within the machine control have to be a multiple of the lowest coin value Pri...

Page 79: ...ices in function 02 please refer to page 6 7 Function 16 Print out vend sales data G 26 4000 Professional and Simplex V By using this function you can determine the printout format In order to print out the vend sales data for the changer Simplex V or Professional please activate the appropriate position within function 16 Please refer to the Manual for Changer Series G 26 4000 function 16 0 Time ...

Page 80: ...ble from the printer early If this function is active you can only use a printer without print key i e a printer in which the print key is shunted and thus active permanently 0 Audit data is erased after printout 1 Audit data is only eased after initilization with a data retrieval unit for service 0 Time is printed 1 Time is not printed 0 Vend sales data per price line is printed 1 Vend sales data...

Page 81: ...ubes 24 00 moneyinsertedduringtubefilling operator CHANGE 0 00 changepaidout 0 00 moneypaidoutduringinventory 0 00 erased remaining credit TUBE STORE 28 00 SALES 13 00 CYCLES 40 0 numberoftestsales CASHLESSCARD SALES 7 50 turnoverusingGLOBOCard CYCLES 30 numberofvendsusingGLOBOCard DISCOUNT 8 20 totalvalueofdiscountandsubsides 20 numberofsubsidiesandfreevends CASH TO CARD 0 00 credit tocards reloa...

Page 82: ...ng of maximum number of coins per tube 5 Function 22 02 Setting of committed to vend even when tubes are empty 6 Function 31 Programming of free vend for token 7 Function S 99 Standard setting 8 Function 0401 a Display of price for selected product b Working with two price lists only G 26 4000 6 4 price 9 Function 02 Price setting for two price lists only G 26 4000 6 4 price 10 Function 10 11 Disp...

Page 83: ...lvendswithtoken sinceinstallation 08 09 Totalsaleswithtoken sincelastprintout 09 09 Totalvendswithtoken sincelastprintout Explanation Theadditionalsalesandvenddatarefertothetokensprogrammedwithinthechanger Usingfunction03 youcanprogrammetokenvalues pleasereferalsotothe ManualforChangerSeriesG 26 4000 The totalvalueofallacceptedtokensisstoredwithinthechanger Ifatokenisusedforpayingitisnotnecessaryt...

Page 84: ...allation Cashtocashbox E 0701 865 20 Cashtotubes E 0702 250 00 Changepaidout E 0703 175 60 Cashtotubes E 0704 duringfillingoftubes 315 30 Moneypaidout E 0705 duringinventory 113 00 Credit to card E 0706 78 80 Receiptsof E 0707 billvalidator 670 00 Erased residual E 0708 credit 26 30 Totalamountof E 0709 acceptedtokens 120 60 Erasedtokenamount E 0710 11 70 Returntobase F 07 function Standby P or sh...

Page 85: ...ars 20 Erasevalue E and 2501 simultaneouslyuntil 00 00 appears Displayofmaximum P 2502 numberofcoins 00 inmiddletube Changeasdescribedabove Displayofmaximum P 2503 numberofcoins 00 inrighttube Changeasdescribedabove Returntobase F 25 function Standby P or shutsdown Ifthemaximumnumberofcoinsisreachedthisisrepresentedbythecharacter A duringtubefilling Ifnovalueisprogrammed display 00 themaximumnumbe...

Page 86: ...function2202 thefeature committedtovend remainsvalidevenwhen tubeempty Action Key Display Selectfunction Funtil 22 22 appears Displayof E 2201 tubeempty condition 00 Displayof committedto P 2202 vendwhentubeempty 0 Changesetting 2202 1 Returntobase F 22 function Standby P or shutsdown 0 Uncommittedtovendwhen tubeempty 1 Committedtovendwhen tubeempty 6 Function 31 Programming of free vend for token...

Page 87: ...tokenvalueswithinfunction03 pleasereferto ManualforChanger SeriesG 26 4000 aredisplayed butnotconsidered Action Key Display Selectfunction Funtil 31 31 appears Displaysetting E 31 000 Selectdigittobe Puntildesired 3101 changed digitflashes 000 Changesetting 3101 010 Returntobase F 31 function Standby P or shutsdown Example 0 no free vend with token 1 1 free vend with token 2 0 no free vend with to...

Page 88: ...approximately1 5secondsappears AA WhenexecutingtheservicefunctionS 99againthestoredchangersettingisreestablishedandthedisplay shutsdown Standardsetting 1 Valuesfrom00 10upto01 00 indecimalsteps areassignedtoprices1to10 2 Noacceptanceandchangelimitation function03 3 Token 1 00 50 token 2 01 00 token 3 01 50 function 03 4 Singlevend Resetline8 function04 5 Nosinglecoininhibit function15 6 Noprintout...

Page 89: ...e credit within the changer is not sufficient for the vend Thus the customer realizes how many coins he has to insert The operator is able to check easily the set vend prices 1 Display of time 1 Cigarette mode 1 Display of credit in single vend 1 Delayed reset Please refer to the Manual for Changer Series G 26 4000 function 0401 1 Ecological function 1 Two price lists only valid for G 26 4000 6 4 ...

Page 90: ...gle vend 1 Delayed reset 1 Display of price for selected product 8b Function 0401 Working with two price lists only G 26 4000 6 4 price TheG 26 4000 64 pricechangercanprocesstwopricesperproduct Thepricesarecombinedintwo pricelists Theswitchoverfromonepricelisttotheotheronedependsontheperiodofvalidity Itispossible thatduringacertainperiodthemachinesellsthe productsatamorefavourableprice Forexamplet...

Page 91: ...eevend price 00 00 Action Key Display Selectfunction Funtil 02 02 appears Displayof1stprice E 02 pricelistI I 1 00 10 Displayof2ndprice P 02 pricelist I I 2 00 50 etc until4thpriceisreached Displayof1stprice P 02 pricelist II II 1 00 20 etc Assuming the price to be changed is displayed Increasebylowestcoin once 02 value I 1 00 20 Multipleincreaseby continuously 02 lowestcoin value I 1 00 70 Rapidi...

Page 92: ...s within function 0401 see page 9 and execute price setting for two price lists see page 10 Action Key Display Selectfunction Funtil 10 10 appears Display Salesselection1 E 10 1 ofpricelistI 00 10 Display Numberof E 11 1 vendswithselection1 1 of pricelistI etc untilprice4isreached Display Salesselection1 E 10 II 1 ofpricelistII 00 20 Display Numberof E 11 II 1 vendswithselection1 2 ofpricelistII e...

Page 93: ...mation 5 93 Note If two price lists are used within the changer the printout also includes the data for both price lists Example Sales Vends Price list 1 S1 00 00 C1 0 S2 00 00 C2 0 S3 00 00 C3 0 S4 00 00 C4 0 Price list 2 S1 00 00 C1 0 S2 00 00 C2 0 S3 00 00 C3 0 S4 00 00 C4 0 ...

Page 94: ...il 24 24 appears Display start E 2401 00 00 Selectdigitto Psequentially 2401 bechanged 00 00 Changedigit untildesired 2401 valueappears 06 00 Display end E 2402 00 00 Selectdigitto Psequentially 2402 bechanged 00 00 Changedigit untildesired 2402 valueappears 10 00 Returntobase F 24 function Standby P or shutsdown Intheaboveexample function2401 6 00 function2402 10 00 thechangerwillconsiderthesecon...

Page 95: ...34 Machine No 1 4 digits 123456 Machine No 4 digits 09 10 1992 AUDIT0 1 AUDIT1 1 TOTAL SALES S 10 00 C 5 CASHLESSCARD Onlywhencardsystemisactivated S 2 00 Sales with card since installation C 1 Cycles with card since installation C 2 00 Credit to card since installation OFF ON 4 TO CASHBOX 15 00 0 00 TO TUBES 0 50 0 00 CHANGE 5 50 0 00 0 00 Erased credit unable to be paid back TUBE STORE 0 20 SALE...

Page 96: ...asedimmediately butafteravend afterinsertionofacoinor afterpressingthereturnlever Datareferringtothefillingleveloftubesaswellasthecoinssortedintotubesaretransmittedtothe vendingmachinecontrol ifthemachinecontrolrequiresthisdata onlyBDV Iftheconditionfor tubeempty isfulfilled thecoinsinhibitedbyfunction17 Coinstobeinhibited areenabled if usercardiswithintheGLOBOCardsystem reloadingofcardisallowed i...

Reviews: