Function 19 = Communication with a Card System
G-26.4000 Standard and G-26.4800 Professional
Attention: A ‘1’ may only be programmed, if a credit card system is connected to the changer.
When you connect a GLOBO Card system, please refer to the installation instructions for the
GLOBO Card system.
Action
Key
Display
* Select function
F until
19
19 appears
* Display setting
E
19
0
* Change setting
+
19
1
* Return to base function
P
19
* Programme new setting
P or +
shuts down
Note: 0 = no card system available
1 = card system connected
The fault code 33 appears, if
- the card system is switched off
- the connecting cable is defective
- no card system is available, however, a ‘1’ is programmed
The display shuts down after approximately 2 minutes. The changer no longer attemps to
communicate with the card system and the fault code is recorded.
The communication with the card system can be reestablished as follows:
* Key F
fault code --33-- appears
* Key F again
display shuts down and card system responds again