![NRI G-26.4000 Series Manual Download Page 27](http://html.mh-extra.com/html/nri/g-26-4000-series/g-26-4000-series_manual_1714027027.webp)
Manual G-26.4000:
Page 27
National Rejectors, Inc. GmbH, Germany
Function 03 = Acceptance and Change Limitation and Setting of Tokens
Action
Key
Display
* Display of set token 1
P
0303
00.10
* Increase by lowest coin
+ once
0303
value
00.15
* Increase by multiple of
+ continuously
0303
lowest coin value
00.40
* Rapid increase (100 times
E
0303
lowest coin value)
05.40
* Display of set token 2
P
0304
01.00
Changes as described above
* Display of set token 3
P
0305
02.00
Changes as described above
* Return to base function
P
03
* Return to standby
P or +
shuts down
Note:
For each vend only one token is accepted, i.e. after insertion of a token the unit goes
automatically into mode ‘committed to vend’.Further insertion of coins is possible.
Setting of Tokens