National Rejectors, Inc. GmbH, Germany
Communication Audit Unit
Function 18 = Communication with Audit Unit
G-26.4800 Professional and G-26.4400 SIMPLEX V
An audit unit, alreday integrated within the machine control, is able to communicate with a
G-26.4400 SIMPLEX V and G-26.4800 Professional.
Attention: A ‘1’ may only be programmed, if an audit unit is available.
Action
Key
Display
* Select function
F until
18
18 appears
* Display of setting
E
18
0
* Change digit
+
18
1
* Return to base function
P
18
* Programme change
P or +
shuts down
Note: 0 = no audit unit available
1 = connected with audit unit
The fault code 32 appears, if
- audit unit switched off
- vendor cable possibly is defective
- no audit unit connected, however, a ‘1’ is programmed