4. Transport and Connection of Unit
Transport
o Before transport please empty all tubes
o Transport and storage in factory packing prevents damage
o No transit fixings required
Attention
Components behind validator are at line voltage.
Always
unplug changer
before
removing validator.
Always
refit the safety screw.
Prior to installation
* Check that changer is correct for your machine
* Check operating voltage and change if necessary (switch S1 on interface module)
(Only units for 110.. 240 Volts).
Installation
o Connecting cable to vendor must not yet be plugged
* Mount changer
* Unfasten safety screw (see figure)
* Remove validator
* Secure changer with screws
* Refit validator
* Fix safety screw
* Connect non-fused green/yellow earth lead
* Plug to machine
* Check that motors are in standby state (key ‘+’ twice)
* Fill change tubes with at least 20 coins each (see ‘Filling Change Tubes’ page 18)
Transport/Connection