Chapter 6 Ethernet Configuration
SMART7 Installation and Operation User Manual v6
95
Figure 29: Base/Rover Ethernet Setup—OEM7 Receiver
1. Connect your computer to both OEM7 receivers using null modem serial cables or USB cables.
2. Establish a connection to the receiver using either NovAtel Connect or another terminal program. This con-
nection is used to send the commands in this procedure to the receivers.
For information about establishing a connection using NovAtel Connect, refer to the Help
within NovAtel Connect.
NovAtel Connect version 2.0 or greater is required for OEM7 receivers. Download the
latest NovAtel Connect software and documentation from
3. Connect the power cables to both of the OEM7 receivers and apply power to the receivers.
4. Connect the Ethernet cables to the Ethernet ports on both OEM7 receivers.
5. Establish an Ethernet connection, either static or dynamic configurations. Refer to
on page 91 or
Dynamic IP Address Configuration
on page 93 for more information.
6. Send the following commands to each receiver either through serial or USB ports:
Base
:
FIX POSITION <lat> <long> <height>
INTERFACEMODE ICOM1 NONE RTCA off
LOG ICOM1 RTCAOBS2 ONTIME 1
LOG ICOM1 RTCAREF ONTIME 10
LOG ICOM1 RTCA1 ONTIME 5
SAVECONFIG
Rover
: