Chapter 6 Ethernet Configuration
SMART7 Installation and Operation User Manual v6
96
ICOMCONFIG ICOM1 TCP <base ip address>:<base port #>
INTERFACEMODE ICOM1 RTCA NONE OFF
LOG BESTPOSA ONTIME 1 (optional)
SAVECONFIG
Use the
BESTPOS
log to confirm that the OEM7 rover is in RTK mode.
6.5 Large Ethernet Port Data Throughput
For high data rate Ethernet logging using TCP/IP, disable Windows Delayed Ack Algorithm (DAA) for complete
data logging. If you do not disable DAA, there will be data gaps due to the Windows Ethernet buffer.
If done incorrectly, changing the Windows Registry may impair the operation of the computer.
Editing the Windows Registry is for advanced Microsoft Windows users only. NovAtel Inc. is not
able to provide any technical support for any actions taken regarding information found in
Microsoft’s Knowledge Base.